Trail ignition de-
When this function is activated, the ignition point of the trail arc always depends on the
lay
present phase of the lead arc. The start parameters of the trail arc are automatically adapt-
ed to the prevailing conditions of the lead arc.
The trail arc starts without contact and considerably more smoothly. This prevents or re-
duces the number of failed ignitions.
Automatic (auto) mode implements an optimum ignition delay.
When set manually, an ignition delay of 0 - 2 seconds can be set. The start of the trail arc
is synchronized.
The function can be deactivated. In this case the trail arc is ignited immediately and is not
synchronized.