Notice. If not avoided, the following could result in property damage.
Do not attempt to fill the coolant reservoir when it is installed in the projector chassis.
Fill the coolant to the recommended level only. Do not fill above the maximum level line shown
on the reservoir unit.
1. Remove the coolant reservoir (on page 62).
2. Ensure the coolant reservoir unit is placed on a separate surface.
3. Use a flat-head screwdriver to open the top cap on the reservoir fill port.
4. Pour the required coolant (Koolance LIQ-740PR P/N: 003-005179-XX) into the fill port.
Fill only to the recommended level.
5. Replace the top cap on the reservoir fill port.
6. Using the flat-head screwdriver, tighten the top cap to seal it.
7. Use a soft cloth to wipe away any coolant that drips outside the reservoir.
8. Reinstall the coolant reservoir in the projector.
Cinema 4K-RGB Service Guide–CP4315-RGB, CP4320-RGB, CP4325-RGB, CP4330-RGB
020-102713-03 Rev. 1 (11-2019)
Copyright
2019 Christie Digital Systems USA, Inc. All rights reserved.
©
Service setups
29