Selection Of The Default Setting Used; Connectable Peripherals; Arm / Disarm Without Entry / Exit Delay; Arm / Disarm With Entry / Exit Delay - Bosch ICP-MAP5000-2 Installation Manual

Hide thumbs Also See for ICP-MAP5000-2:
Table of Contents

Advertisement

74
en | Appendices
8.2.1

Selection of the Default Setting Used

8.2.2

Connectable Peripherals

To comply with the requirements for proper functioning of the panel (i.e. detection and
forwarding of intrusion, hold-up, tamper and trouble states), only peripherals may be
connected that are certified in accordance with EN 50131 Grade 3 or Grade 4.
8.2.3

Arm / Disarm Without Entry / Exit Delay

Arming takes place outside the secured area, e.g. with arming device
Program two outputs for signaling the armed / disarmed state
Secure access route against unauthorized entry in armed state, e.g. by installing a blocking
element
8.2.4

Arm / Disarm With Entry / Exit Delay

Arming takes place inside the secured area, e.g. with control center
2014.12 | 13 | F.01U.168.332
Select EN50131 Grade 3 as the default property values set, also refer to
Standard-Compliant Programming, page 59
The programming must not be installed on the panel if panel validation
in accordance with EN 50131 Grade 3 fails.
Include new area if not yet present
Connect a free input with the device key switch
Using the wizard, select the type Static or Dynamic, the user and function of the key
switch Arm / Disarm Area. Now select the area that is to be armed / disarmed. For exit
delay, select No Delay.
Select the area in the properties field of the Key Switch > Area.
In the properties field of the Control Center, include the area in the scope Local Area or
Additional Areas in Scope
Connect one free output in each case with the device LED
Using the wizard, program one output with the behavior item Area Armed and a second
output with the behavior item Area Disarmed.
The signal must be time-limited. Enter a corresponding time (typically 10 sec. / maximum
of 30 seconds) for Activation Duration.
Connect a free output with the device LED
Variant A: Blocking element is actively controlled CLOSED. Using the wizard, program an
output with the behavior item Area Armed
or
Variant B: Blocking element is actively controlled OPEN. Using the wizard, program an
output with the behavior item Area Disarmed
The signal must be static; enter 00:00:00 for Activation Duration
Refer to the manufacturer's connection instructions for further information.
Include new area if not yet present
Include control center if not yet present
Include the area in the scope of the control center: Local Area
Program control center for arming with exit delay: Use Area Normal Delay Time