Install And Connect The Tamper Switch - Bosch ICP-MAP5000-2 Installation Manual

Hide thumbs Also See for ICP-MAP5000-2:
Table of Contents

Advertisement

48
en | Cable Connections
1.
2.
Figure 3.11 ICP-MAP0007 DE Module Connections
3.7

Install and Connect the Tamper Switch

Install the ICP-MAP0050 Control Panel Enclosure Tamper Switch in the ICP-MAP0110 Control
Panel Enclosure.
Install the ICP-MAP0055 Expansion Enclosure Tamper Switch in the ICP-MAP0120 Expansion
Enclosure.
How to install the tamper switch onto the rail
4
2014.12 | 13 | F.01U.168.332
If a DR2020 Printer is used, connect the ICP-MAP0007 DE Module to the DR2020. Refer
to Figure 3.11 ICP-MAP0007 DE Module Connections, page 48.
Connect the supervised sirens and strobes to the DE module outputs. Refer to Figure
3.11 ICP-MAP0007 DE Module Connections, page 48.
Slide the extension piece of the tamper switch to position C as shown in the figure
below.
If a wall tamper plug was installed (refer to Mount the Enclosure, page 17), the position of
the expansion piece of the tamper switch must be chosen in a way that lifting the
enclosure off the wall by > 5 mm leads to reliable activation of the tamper switch.
Installation Manual
MAP5000
Bosch Sicherheitssysteme GmbH

Advertisement

Table of Contents
loading

This manual is also suitable for:

Map5000 seriesIcp-map5000-com

Table of Contents