Overview - Valor L2 1700KN Installation Manual

Direct vent zero clearance gas fireplace
Table of Contents

Advertisement

Installation Planning
Note: This appliance may be installed in outdoor, weather protected environments as defi ned in the GV60CKO
Outdoor Conversion Kit instruction manual.
Surrou
nd
d
d
Pl
l
l a
l
te
w w ith Barrier Screen
(required)
Narr r ow 1" Trim 1775LFB and
wide e r 3-1/2" steel Trim 1750
adjus s table, accept additional
non- - combustible finish over
cement board and
behind trim.
1730CIK's narrow trim
requires HeatShift.
Cement board finishes up to
perimeter of trim.
Note: 1730CIK installs before
cement bo
b
ard.
Wall
ll
Fi
i
ni
i
sh
h
A A ny wall finishes applied
o o ver cement board must
be non-combustible.
Com m bustible mantel are ok
provided they conform to
chart on
pag
p g
p
ge p
p
p
p
age
g
g
g
11.
Combustible Floor
WARNING
Some materials or items, although safe,
may discolor, shrink, warp, crack, peel,
and so on because of the heat produced
by the fireplace. Avoid placing candles,
paintings, photos, and other items
sensitive to heat around the fireplace.
10
Hearth: not required.
If used, must be minimum 4"
below fi replace opening unless
using HeatShift (see "Appendix D—
HeatShift™System" on page 74)
Mantel—See Mantel & Hearth Clearances
Framing—See Framing Requirements
1/2 inch thick non-combustible cement board –NOT supplied
Supplied as vertical outlet, fi eld convertible to horizontal
outlet. Note - Vertical rise required in vent system
Optional HeatShift System
outlets (4)—Required with
1730CIK
Combustible Framing Allowed Beneath Fireplace. When the appliance
is installed directly on carpeting, tile or other combustible material
other than wood fl ooring, the appliance shall be installed on a metal
or wood panel extending the full width and recessed depth of the
appliance.
WARNING
HOT WALL SURFACES! The wall directly
above the fireplace is constructed of non-
combustible materials and, although safe,
it may reach temperatures in excess of
200°F (93°C) depending on choice of trims.
Do not touch. Finish wall using materials
suitable for these temperatures.

Overview

Remote Battery
and Wall Switch Kit
(required) (35-foot wire
length) (supplied)
1700K heater
Remote
Handset
Wall Holder
Electrical
junction box
(not supplied) to
connect power
when using
optional fan, WiFi

Advertisement

Table of Contents
loading

This manual is also suitable for:

L2 1700kp