Co-Linear Conversion; Installation Into Existing Fireplace Cavity - Valor L2 1700KN Installation Manual

Direct vent zero clearance gas fireplace
Table of Contents

Advertisement

Venting
Installation into existing fi replace cavity
Note: Co-linear portion of vent system may only be
installed within a solid-fuel burning fi replace and
chimney.
The appliance must not be connected to a chimney fl ue
serving a separate solid-fuel burning appliance.
Requires the Valor Co-Axial to Co-Linear appliance
Adapter 1156CLA, two lengths of 2-ply fl exible chimney
liner both approved for venting gas appliances: one 3"
diameter liner for intake and one 4" diameter liner for
exhaust, a 3 x 4 co-linear termination kit and fl ashing.
Firebox zero clearance standoff s supplied with the heater
may be removed to suit this application.
1156CLA Co-Linear Vent Adapter
FRONT
11-11/16"
9-3/8"
4" exhaust
collar adapter
Rules for Co-Linear Venting
• Maximum 40 feet vertical pipe
• Minimum 10 feet vertical
• Maximum off set 8 feet with liners at minimum
45 degrees from horizontal plane
• Restrictor: Not required when using co-linear venting.
Installation
For installation of the adapter to the appliance, see the
instructions supplied with the 1156CLA.
Note: Co-linear fl exible aluminum venting should be
professionally inspected periodically for corrosion
and damage and replaced when necessary. If the
installation does not allow for future inspection or
replacement of the fl exible aluminum venting, then
stainless steel vent liners should be used.
REAR
3" exhaust
collar
4"
1-1/2"

Co-Linear Conversion

3" intake
4" exhaust
liner
liner
Co-linear
adapter
3" min. bend radius
for intake liner and
4" min. bend radius
for exhaust liner
Any fi nishes
applied
around the
fi replace
must be non-
combustible
Co-Linear installation into existing fi replace
Dimensions with 1156CLA Co-Linear Adapter
52"
3" intake
32-3/8"
18-1/8"
Approved 3 x 4 co-linear
termination
Flashing
1 x 3"
intake
liner
and
1156
1 x 4"
Co-linear
exhaust
adapter
liner
Engine
8-5/8"
4" exhaust collar
on the centerline
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

L2 1700kp

Table of Contents