Valor L2 1700KN Installation Manual page 77

Direct vent zero clearance gas fireplace
Table of Contents

Advertisement

Appendix D—HeatShift™System
Suggested Con gurations
Front wall outlet using LDK1 or LDK4
Rear wall outlet using LDK1 or LDK4
Note: Fireplace vent may con ict with plenum.
O set vent around plenum.
Side wall outlets using LDK3
Rear wall outlets using LDK3
Note - When using LDK7, the discharge opening
must be located in the same room as the fireplace.
With LDK7
Not to scale
Corner installations
WARNING
The plenum duct kits are approved
for horizontal discharge ONLY. The
termination duct plates are approved
for vertical upward discharge ONLY. DO
NOT install plenum or termination plates
in oor or ceiling. DO NOT COVER OR
PLACE objects in front of or on top of air
outlet(s). AVOID locating outlet within
7 feet of the oor level as discharge air
temperatures are hot!
D O N O T D I S C H A R G E T H R O U G H
E X T E R I O R W A L L S !
NOTE This duct kit may also be used for outdoor
installations where reduced wall surface
temperatures above the unit are desired.
The discharge grilles must be located under
the weatherproof enclosure described in the
GV60CKO Outdoor Fireplace Conversion Kit
instructions.
77