Electrical Wiring - Valor L2 1700KN Installation Manual

Direct vent zero clearance gas fireplace
Table of Contents

Advertisement

Installation
Install Electrical Wiring (if required)
This section provides information to install the elec-
tric pre-wiring required for use with the optional
1595CFKV2 Circulating Fan Kit and/or the GV60WIFI Kit.
All wiring must be done by a qualifi ed electrician in
accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70 or
the Canadian Electrical Code, CSA C22.1.
Electrical Requirements
1595CFKV2—120 V, 60 Hz, less than 1 amp
GV60WIFI kits—120 V, 60 Hz, less than 1 amp
General Requirements
Optional 1595CFKV2 and WiFi module are powered by a
V-module (sold separately) which plugs into a grounded
receptacle installed within the fi replace enclosure by a
qualifi ed electrician.
Notes
• Fan speed control provided through remote handset.
• Receptacle and box must be located as per these
instructions. Wiring within this box must have a mini-
mum 90°C temperature rating.
Installation
1. Thread the cable through the cable clamp and
through the hole in the lower right hand corner of
the fi replace casing. Do not tighten the clamp yet..
Fireplace
Fireplace
casing
casing
34
Stud
Stud
Pull just enough cable
out front for now to make
termination easier
2. Provide a steel surface mount electrical utility
box (Iberville BC 1110 or equivalent), thread cable
through knock-out in the back of box and through
the cable clamp locking ring (if used).
3. Strip wire and terminate grounded receptacle.
4. Mount the electrical box to the side of the fi replace
casing using self-tapping sheet metal screws. Pull
the excess cable back through the cable clamp and
tighten the locking ring to the cable clamp. Alternate
clamp without locking ring may be used - ensure the
proper clamp is used for the type of cable used.

Electrical Wiring

Advertisement

Table of Contents
loading

This manual is also suitable for:

L2 1700kp