Enable all on-board DC-DC converter for CPU complexes
Implementation of power-up timing sequence requirements
Supervision of power rails for CPU complex
2
I
LPC target interface for each CPU
1.13.2

Glue CPLD

The Glue CPLD on the Extreme Edge Server runs off management power and is
associated with the BMC and is powered anytime -48V power is present. It implements
these major functions:
Monitor output of low-temperature thermal switch
Enable BMC power under appropriate operating conditions
Implement power-up timing sequence requirements for non-CPU power rails
Supervision of non-CPU power rails
Enable on-board clocks when payload power is stable
2
I
Update configuration of the logic device via I
Reset control
BMC serial routing, routes 1 UART from each CPU to BMC
Control debug LEDs via registers
Watchdog timer
LPC slave interface connected to CPU1
Implement status and control registers for SFP+ modules
MC1600 Extreme Edge Server Installation and Use (6806870A02B)
C slave interface connected the BMC
Power control of both CPUs
Power fail registers for both CPUs
Control and status registers for each CPU
Error status registers for each CPU
Port 0x80 for each CPU, select CPU via SMBus register
SERIRQ for KCS interrupt support
Control and status registers
Can be used to update configuration of the logic device
C slave interface connected the BMC
System Overview
2
C interface
79