Table 5-3
Request Data
Response Data
5.2.2.1.1 SMART EC IPMI OEM Command Summary
These OEM commands are specific for the Extreme Edge Server. OEM commands for
other similar platforms may vary.
Table 5-4
Command
Set FRU Instance Power State
Get FRU Instance Power State
Set Chassis Power Policy
Get Chassis Power Policy
Set Aggregated Temperature
Sensor
Get Aggregated Temperature
Sensor
Get FRU Present State Version 0
Get FRU Present State Version 1
Set Chassis Address Info
Get Chassis Address Info
5.2.2.1.2 Power Management
In addition to the standard IPMI Chassis Control command, the following OEM commands
are created for a fine power control over the chassis.
MC1600 Extreme Edge Server Installation and Use (6806870A02B)
General OEM Command Structure
1
0xae
2
Version of the command
(n)
Request payload data if any, n bytes
1
0xae
2
Completion code
(m)
Response payload data if any, m bytes
SMART EC IPMI OEM Command Summary
NetFn
Command
OEM/Group
0x34
OEM/Group
0x35
OEM/Group
0x36
OEM/Group
0x37
OEM/Group
0x3C
OEM/Group
0x3D
OEM/Group
0x47
OEM/Group
0x47
OEM/Group
0x48
OEM/Group
0x49
Software Configuration
Privilege
Table
Level
Table 5-5
Administrator
Table 5-6
User
Table 5-7
Operator
Table 5-8
User
Table 5-9
Administrator
Table 5-10
User
Table 5-11
User
Table 5-12
User
Table 5-13
Administrator
Table 5-14
User
111