SMART Embedded Computing MC1600 Installation And Use Manual

Extreme edge server
Table of Contents

Advertisement

Quick Links

MC1600 Extreme Edge Server
Installation and Use
P/N: 6806870A02B
January 2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MC1600 and is the answer not in the manual?

Questions and answers

Summary of Contents for SMART Embedded Computing MC1600

  • Page 1 MC1600 Extreme Edge Server Installation and Use P/N: 6806870A02B January 2020...
  • Page 2 Computing” and the SMART Embedded Computing logo are trademarks of SMART Modular Technologies, Inc. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. These materials are provided by SMART Embedded Computing as a service to its customers and may be used for informational purposes only. Disclaimer* SMART Embedded Computing (SMART EC) assumes no responsibility for errors or omissions in these materials.
  • Page 3: Table Of Contents

    10 Gigabit Ethernet ............61 MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 4 1.18 Ordering and Support Information ......... . . 82 MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 5 Introduction ............. 97 MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 6 Related Documentation ............123 MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 7 Location of Serial and Assembly # Labels ....... 50 Figure 1-4 MC1600 Extreme Edge Server - Dual CPU Block Diagram ....52 Figure 1-5 High Level Broadwell-DE Block Diagram .
  • Page 8 List of Figures MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 9 Get Chassis Address Info ..........120 MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 10 SMART EC Documentation ......... . . 123 MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 11: About This Manual

    Chapter 4, System Installation on page 91 provides instructions for installing and removing the MC1600 Extreme Edge Server in a rack or cabinet. It also gives information and procedures for grounding, powering up and down, and disconnecting the server from the power feed.
  • Page 12 Original Equipment Manufacturer PCIe PCI Express Power Entry Module Small Form-factor Pluggable Stock Keeping Unit (Intel SKU Numeric Digits) Serial Presence Detection Serial Peripheral Interface Trusted Platform Module xHCI eXtensible Host Controller Interface MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 13 Logical OR Indicates a hazardous situation which, if not avoided, could result in death or serious injury Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 14 This manual has been revised and replaces all prior editions. Part Number Publication Date Description Rebrand to SMART Embedded Computing template. 6806870A02B January 2020 Updated Safety Notes in English and German; added French Safety Notes. 6806870A02A April 2019 Initial Release MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 15: Safety Notes

    Failure to comply with these precautions or with specific warnings elsewhere in this manual could result in personal injury or damage to the equipment. SMART Embedded Computing intends to provide all necessary information to install and handle the product in this manual. Because of the complexity of this product and its various uses, we do not guarantee that the given information is complete.
  • Page 16 AWG rating of the overcurrent protection device, see NEC Table 310.16 and other national regulations.  The protective bonding conductor depends on your power distribution topology. Make sure that you use an appropriate protective bonding conductor regarding the rating of the branch circuit protection. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 17 Use caution when pulling the system out of the rack, as it could fall and cause personal injury. Personal Injury The system is heavy and improper handling may lead to muscle strain or back injury. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 18 Disconnect the system from any AC or DC power or turn the system board power (payload power) off through the Board Management Controller (BMC). For more information, refer to the MC1600 Extreme Edge Server Installation and Use manual. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 19 The front panel, including the air filter (if equipped), is mounted to the system by alignment pins and holding clips on both sides of the system. When mounting the front panel to the shelf, align it accurately to avoid damage to the frame or front panel. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 20 To avoid an overload of the system, check the total power consumption of all components installed. Make sure that the individual output current of any source stays within its acceptable limits (see the technical specification of the respective source or component). MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 21 Running the fans at high speed for a long time may shorten the life of the fans and may exceed allowable acoustic noise limits. Replace the fan tray (or fan modules) without delay. Personal Injury–Rotating Fans Inserting tools or fingers into operational fans may cause personal injury. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 22 Make sure the TPE connector of the system is connected only to Safety Extra Low Voltage (SELV) circuits.  If in doubt, ask your system administrator. For more information, see the documentation of the respective product. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 23 PCB or the battery holder. Environment Environmental Damage Improper disposal of used products may harm the environment. Always dispose of used products according to your country’s legislation and manufacturer’s instructions. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 24 Safety Notes Safety Notes MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 25: Notice De SĆ©curitĆ©

    à ces précautions ou aux avertissements spécifiques contenus ailleurs dans ce manuel, peut engendrer des lésions corporelles ou dommages à l’équipement. SMART Embedded Computing prévoit dans ce manuel de fournir toute l’information nécessaire pour installer et manipuler le produit. En raison de la complexité de ce produit et de ses diverses utilisations, nous ne pouvons pas garantir que les informations fournies sont complètes.
  • Page 26 Afin de commencer l’installation et le câblage de votre nouveau système, tenez compte de ces instructions : MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 27 être correctement protégée contre les surtensions/transitoires. Une évaluation plus poussée de la sécurité électrique serait requise.. Endommagement du système La contamination environnementale peut nuire à l’opération du système. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 28 Effectuez une connexion de mise à la terre avant de connecter le bloc d'alimentation. Endommagement du système De mauvais réglages de câbles de démarrage peuvent rendre le système inutilisable. Ne modifiez jamais les paramètres des câbles de démarrage. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 29 Déconnectez le système de toute alimentation CA ou CC ou mettez la carte système (alimentation de la charge utile) hors tension via le Contrôleur de gestion de carte (BMC). Pour plus d’information, référez-vous au manuel MC1600 Extreme Edge Server Installation and Us.
  • Page 30 Cet équipement est conçu pour permettre la connexion du conducteur mis à la terre du circuit d'alimentation en CC au conducteur de mise à la terre de l'équipement. Si cette connexion est établie, toutes les conditions suivantes doivent être remplies : MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 31 être corrompue. Dans un tel cas, le produit restera probablement dans un état inutilisable et nécessitera un reconditionnement par des services de réparation qualifiés. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 32 Un calibrage non conforme peut endommager votre produit. Faites extrêmement attention de ne pas renverser la polarité lorsque vous connectez le fil d’alimentation. Ventilateurs Endommagement du système Un refroidissement insuffisant peut endommager le système. Nehmen Sie deshalb den Austausch ohne Verzögerung vor. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 33 SMART EC local. Dommages au câble Ne pas plier les câbles. Le fait de plier un câble à fibre optique endommage le câble et empêche la transmission des données. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 34 Perte de données L'installation d'un autre type de batterie que celle montée à la livraison du produit peut causer une perte de données. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 35 PCB ou le support de batterie. Environnement Dommage Environnemental Une disposition impropre des produits usagés peut être nocif pour l’environnement. Éliminez les produits usagés toujours conformément à la législation de votre pays et aux instructions du fabricant. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 36 Notice de Sécurité Notice de Sécurité MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 37: Sicherheitshinweise

    Verletzungen oder Schäden am Produkt zur Folge haben. SMART Embedded Computing ist darauf bedacht, alle notwendigen Informationen zum Einbau und zum Umgang mit dem Produkt in diesem Handbuch bereit zustellen. Da es sich jedoch um ein komplexes Produkt mit vielfältigen Einsatzmöglichkeiten handelt, können wir die Vollständigkeit der im Handbuch enthaltenen Informationen nicht garantieren.
  • Page 38 Anforderungen erfüllt werden. Beachten Sie folgende allgemeinen Sicherheitshinweise vor der Installation und Verkabelung des Systems:  Eingeschraenkter Zugangsbereich: Beabsichtigt für die Installation an einem abgegrenzten Ort mit Zugang nur von geschultem Personal. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 39 Verbindung angemessen gegen Überspannung geschützt sein. Und eine weitere Ueberpruefung der elektrischen Sicherheit wäre notwendig. Beschädigung des Systems Verschmutzungen können das System beschädigen. Betreiben Sie das System an einem erschütterungsfreien Ort, an dem weder Staub, Rauch noch elektrostatische Entladungen auftreten. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 40 Stellen Sie vor Anschluss des Systems an den Versorgungsstromkreis unbedingt eine Erdungsverbindung her. Beschädigung des Systems Falsche Jumper-Einstellungen können dazu führen, dass das System nicht mehr funktioniert. Ändern Sie deshalb nie die Einstellungen der Jumper. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 41 Trennen Sie das System von AC- oder DC-Strom oder schalten Sie die Systemplatine (Nutzlast) mithilfe des Board Management Controllers (BMC) aus. Weitere Informationen finden Sie im MC1600 Extreme Edge Server Installation and Use Handbuch. Fehlfunktion Unsachgemaesses Ein- und Ausbau von Karten kann zu einer Fehlfunktion der PCIe Steckplaetze führen.
  • Page 42 Ausrichtungsstifte und Halteklammern an beiden Seiten des Systems am System befestigt. Richten Sie die Frontblende bei der Montage am Regal genau aus, um eine Beschädigung des Rahmens oder der Frontblende zu vermeiden. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 43 Memory des Geräts unterbrochen wird, werden die Änderungen nicht gespeichert oder der Flash Memory kann beschädigt werden. In diesem Fall bleibt das Produkt wahrscheinlich in einem nicht betriebsbereiten Zustand und muss von qualifizierten Reparaturdiensten überholt werden. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 44 Unsachgemäße Verkabelung beschädigt Ihr Produkt. Achten Sie beim Anschließen des Netzkabels besonders darauf, die Polarität nicht umzukehren. Fans Beschädigung des Systems Unzureichende Kühlung kann das System beschädigen. Nehmen Sie deshalb den Austausch ohne Verzögerung vor. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 45 Verkabelung haben, wenden Sie sich an die für Sie zuständige Geschäftsstelle von SMART EC. Beschädigung der Kabel Kabel nicht falten. Durch das Falten eines Glasfaserkabels wird das Kabel beschädigt und die Datenübertragung wird verhindert. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 46 Beschädigung des Blades Unsachgemäßer Einbau der Batterie kann gefährliche Explosionen und Beschädigungen des Blades zur Folge haben. Verwenden Sie deshalb nur den Batterietyp, der auch bereits eingesetzt wurde und befolgen Sie die Installationsanleitung. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 47 Batteriehalterung beschädigt werden. Umweltschutz Umweltschäden Unsachgemäße Entsorgung von gebrauchten Produkten kann die Umwelt schädigen. Entsorgen Sie gebrauchte Produkte stets gemäß der in Ihrem Land gültigen Gesetzgebung und den Empfehlungen des Herstellers. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 48 Sicherheitshinweise Sicherheitshinweise MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 49: System Overview

    ETH1 connects to CPU1 ETH2 connects to CPU2 ETH 1&2 connect to CPU1 on a single CPU board The next figure and table describes the LED location, functions and status. Figure 1-2 Front Panel LEDs MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 50: Cooling

    The BMC monitors all fan tachometer readings, when fans are powered on, and at what speed the fans run. The BMC sets the fan speed based on sensor data within the system. For more information Section 5.2.2.1.4, Aggregated Temperature Sensors on page 116. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 51: Grounding

    The -48V RTN is isolated from logic ground and chassis ground in the system. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 52: Block Diagram

    System Overview System Overview Block Diagram This following block diagram shows the major functions and interfaces of the MC1600 Extreme Edge Server. Figure 1-4 MC1600 Extreme Edge Server - Dual CPU Block Diagram MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 53: Extreme Edge Server Base Board

    The minor differences between the two processors blocks are highlighted using keyword CPU1 for the first processor and CPU2 for the second processor. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 54: Cpu Sku Support

    DIMM Type Ranks Qualified Module Chips Part # X4B08QD8BNTDME-E-AY1 (C-temp) 9706802B79 RDIMM 1 Rank x8 X4B08QD8BNTDMW-E-AY1 (I-temp) 9706802B80 RDIMM 1 Rank x4 16GB RDIMM 2 Rank x8 16GB RDIMM 2 Rank x4 32GB MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 55: Real Time Clock

    On the Extreme Edge Server, the x16 port (PE1) of each CPU is bifurcated into two x8 ports, of which only the first one is used. Connections to the PCIe connector are according following table. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 56: Pci Express Gen2

    5.0Gbps (Gen2) CPU1 Lanes 1-4 Ethernet MAC/PHY A 2.5Gbps (Gen1) CPU1 Lanes 1-4 Ethernet MAC/PHY B (option) 2.5Gbps (Gen1) CPU2 Lanes 1-4 Ethernet MAC/PHY B (default) 2.5Gbps (Gen1) CPU1 Lanes 1-4 2.5Gbps (Gen1) MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 57: Ethernet Interface

    Broadwell-DE supports up to two SPI flash devices using two separate chip select pins. The SPI device is 16MB and operates at 50MHz. A SPI flash device with a valid descriptor must be attached to chip select 0 as the BIOS boot device. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 58: Usb Interface

    The CP2105 device is powered from the host cable so that the terminal session is not lost when system power is cycled. Serial port COM1 of each CPU is routed to the BMC through the Glue CPLD. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 59: Smbus And I C Interface

    PCI cards, etc. There are four SMBus ports on the SoC. The slave interface allows an external microcontroller to access system resources. The diagram below shows the SMBus architecture of each CPU. Figure 1-6 CPU SMBus Architecture MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 60: Lpc Interface

    The PECI interface is connected between CPU and PCH, both integrated in the Broadwell-DE SoC. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 61: 10 Gigabit Ethernet

    SFP+ Port 1 (ETH3) TSC1 10Gbps SFP+ Port 2 (ETH4) TSC1 10Gbps SFP+ Port 3 (ETH5) TSC1 10Gbps SFP+ Port 4 (ETH6) TSC2 10Gbps SFP+ Port 5 (ETH7) TSC2 10G-KR 10Gbps CPU1 MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 62: Sfp+ Ports

    SFP+ port to be used as the Ethernet timing reference for the Ethernet switch. This allows the other SFP+ ports to be synchronized to this timing reference. The diagram below shows the SyncE clocking architecture. Figure 1-7 Synchronous Ethernet Clocking Architecture MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 63: Ieee 1588 Support

    CPUs. For example, a custom card may have x16 card edge, bifurcated into two x8 ports. In this case, it can connect to CPU1 and CPU2, each with a maximum link width of x8. Refer Figure 1-5, High Level Broadwell-DE Block Diagram on page MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 64: Storage

    8806813A29 128GB 2280 MLC NAND Flash AF128GSMJA-AY2 (I- 8806813A26 temp) PCIe Gen3 256GB 2280 MLC NAND Flash PCIe Gen3 512GB 2280 MLC NAND Flash PCIe Gen3 1024GB 2280 MLC NAND Flash MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 65: Connectors

    PERn0 - Lane 0 from Card to CPU1 PRSNT2# - Card Presence Detect Ground Ground PETp1 - Lane 1 from CPU1 to Card Ground PETn1 - Lane 1 from CPU1 to Card MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 66 PERp6 - Lane 6 from Card to CPU1 Ground PERn6 - Lane 6 from Card to CPU1 Ground Ground PETp7 - Lane 7 from CPU1 to Card Ground PETn7 - Lane 7 from CPU1 to Card MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 67 PERn12 - Lane 4 from Card to CPU2 Ground Ground PETp13 - Lane 5 from CPU2 to Card Ground PETn13 - Lane 5 from CPU2 to Card PERp13 - Lane 5 from Card to CPU2 Ground MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 68: 48V Power Connector

    -48V Power Connector The input power connector is Molex 42820-2213 (2806858A05). The pinout of each power connector is as shown. Table 1-10 Input Power Connector Pinout Function -48V RTN (+ input) -48V (- input) MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 69: Sfp+ Module Connectors

    +3.3V RX_LOS 1.11.4 RJ-45 Ethernet Connectors Table 1-12 Ethernet RJ-45 Connector Pinout Function - 10Base-T or 100Base-Tx Function - 1000Base-T ETH_TX+ ETH_DA+ ETH_TX- ETH_DA- ETH_RX+ ETH_DB+ ETH_DC+ ETH_DC- ETH_RX- ETH_DB- ETH_DD+ ETH_DD- MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 70: Usb 2.0 Connector

    Table 1-14 USB 3.0 Connector Pinout Function VBUS SS_RX- SS_RX+ SS_TX- SS_TX+ 1.11.7 DDR4 DIMM Connectors Table 1-15 DDR4 DIMM Pinout Signal Signal Signal Signal VDDQ VDDQ VREF CK0# CK1# VDDQ VDDQ MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 71: Table 1-15 Ddr4 Dimm Pinout

    VDDQ MA13 CS1# VDDQ DQS10 VDDQ DQS10# ODT1 DQS1# VDDQ DQS1 VDDQ DQ14 DQ15 DQ10 DQ36 DQ11 DQ37 DQ20 DQ32 DQ21 DQ33 DQ16 DQS13 DQS13# DQ17 DQS4# DQS11 DQS4 DQS11# DQ38 DQS2# MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 72 DQS3 DQ47 DQ30 DQ42 DQ31 DQ43 DQ26 DQ52 DQ27 DQ53 ECC4 DQ48 ECC5 DQ49 ECC0 DQS15 DQS15# ECC1 DQS6# DQS17 DQS6 DQS17# DQ54 DQS8# DQS8 DQ55 ECC6 DQ50 ECC7 DQ51 ECC2 DQ60 MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 73 Signal Signal ECC3 DQ61 RESET# DQ56 VDDQ CKE1 DQ57 CKE0 DQS16 VDDQ VDDQ DQS16# DQS7# ACT# VDDQ DQS7 DQ62 VDDQ ALERT# DQ63 MA12 DQ58 VDDQ MA11 DQ59 VDDQ VDDQ VDDSPD VDDQ VDDQ MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 74: Nvme Module Connectors

    PETn1 - Input to Module PETp1 - Input to Module SMB_CLK PERn0 - Output from Module SMB_DATA PERp0 - Output from Module ALERT# PETn0 - Input to Module PETp0 - Input to Module PERST# MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 75 System Overview Table 1-16 NVMe Module Pinout (continued) Function Function 100MHz Refclk- 100MHz Refclk+ Susclk +3.3V +3.3V +3.3V MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 76: Baseboard Management Controller (Bmc)

    Flash: Dual 64MB, main socket and backup device soldered – Storage flash: 16MB  Ethernet PHY – RGMII to SGMII conversion going to Ethernet switch – RGMII to 10/100/1000Base-T going to front panel RJ-45 MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 77: Bmc Subsystem Features

    8x debug LED (green), 1x heartbeat LED (red) – 4x debug switch (DIP switch type) – Console output via 3-pin header, R-232  PCIe – PCIe GEN1 x1 link (endpoint) to CPU1 (root) MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 78: Bmc Private I C Buses

    1.13.1 CPU CPLD The CPU CPLD on the Extreme Edge Server runs off payload power and is associated with the two CPU complexes. It implements these major functions: MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 79: Glue Cpld

    BMC serial routing, routes 1 UART from each CPU to BMC  Control debug LEDs via registers  Watchdog timer  LPC slave interface connected to CPU1  Implement status and control registers for SFP+ modules MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 80: Power Supply

    CPU power-up sequence is initiated. The power-up sequence continues until the S0 state is reached. The processors on the card can be powered up/down independently. This requires a dual power-up state machine design in the CPU CPLD. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 81: 48V Power Domain

    SoC which then internally generates the output clocks that are required by all the platform components. 1.15.2 Other Clocks The 156MHz clock for the Ethernet switch is provided by the SyncE PLL as described previously in this document. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 82: Reset Structure

    OFF positions (default). 1.18 Ordering and Support Information The data sheet for the MC1600 Extreme Edge Server contain a complete list of available product variants and accessories. Refer to the Appendix A, Related Documentation consult your local SMART Embedded Computing sales representative for the availability of other variants.
  • Page 83: Site Preparation

    Chapter 2 Site Preparation Introduction This chapter provides information on unpacking the MC1600 Extreme Edge Server, safety precautions, and requirements for the product. Included are the environmental and power requirements, mounting options, cooling considerations, acoustic noise control, and dimensions and weight of the product.
  • Page 84: Power Requirements

    Dimensions W x H x D Weight 1U (H) x 19” (W) x 12” (D) 12.4 lbs Server including DIMMs, M.2 SSDs, mounting ears, and PCIe filler panel (44.5mm x 482.6mm x 304.8mm) (5.6 kg) MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 85: Esd Prevention

    If the rack is equipped with stabilizing devices, make sure that they are installed and extended so that the rack is secure. Then proceed to mount or service the system. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 86: Electromechanical

    Characteristic Condition   C to 65 C without optional heater Operating temperature   C to +65 C with heater* (at the air inlet)   Storage temperature C to +70 MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 87: Electronic Waste Disposal

    EN 55024 (EU) FCC 47 CFR Part 15 Subpart B (US), Class EMC requirements ETSI EN 300 386 Class A Electromagnetic Compatibility and Electrical Telcordia GR-1089-CORE Safety-Generic Criteria for Network Telecommunications Equipment, Issue 6 MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 88: Figure 2-1 Location Of Regulatory Labels

    Site Preparation Site Preparation Figure 2-1 Location of Regulatory Labels MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 89: Fru Installation

    Custom brackets may be required. The PCIe slot receives 12V (5.5A max) and 3.3 V (3.0A max) power from the card. The PCIe slot can accommodate cards with up to 75W power dissipation. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 90: Sfp/Sfp+ Modules

    Broadcom/Avago ABCU-5700RZ (SFP, 1000Base-T)  Finisar FTLX1471D3BCL (SFP+, 10GBase-LR)  Finisar FTLX1471D3BCV (SFP+, dual-rate 1G/10GBase-SR)  Finisar FTLX8571D3BCL (SFP+, 10GBase-SR) Refer to the documentation for your specific SFP+ module for installation instructions. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 91: System Installation

    The connectivity of the RJ-45 ports to CPU1 and/or CPU2 is covered in Figure 1-1 on page Section 1.7.2.2, PCIe-Based Gigabit Ethernet on page Install the Extreme Edge Server in the Cabinet For installation recommendations regarding outside installations, go to Mounting Options on page MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 92: Ground The Server

    3. Connect the power connector to the DC power supply and insert the connector into the Extreme Edge Server. 4. Turn on the external feed power. The input power LED on the front panel turns green. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 93: Connect The Serial Console

    The USB port on the front of the labeled CONSOLE uses a USB-to-dual serial interface from Silicon Labs (CP2105). Connect a USB Type-A to USB Type-A cable with one end to the CONSOLE on the MC1600 and the other end to the display console. For Windows 7 or later: Teraterm Drivers are automatically installed when connecting the cable.
  • Page 94: 4.3.5 Connection Of A Usb Device

    Perform the server power down via the BMC's web interface or by pressing the power button on the I/O panel. This guarantees a clean shutdown of all system circuitry. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 95: Disconnect From The Power Feed

    2. Disconnect all cables from the PCIe cards and from the I/O panel. 3. Remove the earth ground connection. 4. Loosen and remove the mounting screws. 5. Remove the system from the rack. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 96 System Installation System Installation MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 97: Software Configuration

    Software Configuration Introduction The MC1600 Extreme Edge Server comes with software and firmware preinstalled and ready for use when the system powers up. Each of the two CPUs boot up with an Insyde UEFI BIOS that is accessible via the CPU's serial port, refer to...
  • Page 98: Figure 5-1 Single Cpu Variant

    This allows CPU2 to PXE boot from CPU1. See the following figures for the single and dual default network diagrams. Figure 5-1 Single CPU Variant ETH1 ETH2 Front Panel CPU 1 ETH1 = 172.26.1.10 ETH2 = not configured bcm interface Broadcom Switch MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 99: Firmware Upgrade

    1. Set your IP address on CPU1 or external server, to the same subnet as BMC. (192.168.201.xxx) 2. Download hpm.1 image to CPU1 or external server and execute the following command: ipmitool –I lanplus –H 192.168.201.9 –z 0x7fff –U admin –P admin hpm upgrade <image name> MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 100: 5.2.1.2.2 Bios Upgrade

    The output of the Show Operation is similar to the output of the Query Operation. A sample output of the BIOS image is shown below. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 101 Upgrade Operation uploads the firmware image to the device. Before the upload process, the firmware image is validated first and the FCU verifies if the image is applicable to the firmware device. To upgrade BIOS, use the following command: $ fcu –uf <BIOS image>.fri MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 102: 5.2.1.2.3 Cpld Upgrades

    -I lanplus -U admin -P admin -H 192.168.201.9 -z 0x7fff hpm upgrade mc1600-cpld-glue-x.x.x.hpm activate CPU CPLD Upgrade ipmitool -I lanplus -U admin -P admin -H 192.168.201.9 -z 0x7fff hpm upgrade mc1600-cpld-cpu-x.x.x.hpm activate MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 103: 5.2.1.2.4 Cpu Cpld Upgrade Using Fcu Utility

    Show Operation Verification of CPLD Firmware Image fcu -vf <Fri file image> is the command used for verifying a CPLD firmware image. The following screen shows an example output of the command. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 104: Broadcom Switch

    5.2.1.3 Broadcom Switch The MC1600 contains a Broadcom BCM53402 8-port Ethernet switch. Each port supports 10GbE. The eight ports are connected as follows: 1 - Front panel SFP+, labeled ETH3 (BCM port xe0) MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 105 Notice in the help output that certain characters are capitalized in the command names. The capital letters represent the minimum letters necessary (or shortcut) to issue the command. For example to call the PortStat command, the shortcut would be ps. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 106 1000 packets on port xe0, assuming the link is up: BCM.0> tx 1000 pbm=xe0 To display the currently configured VLANs, use the vlan show command. For example: BCM.0> vlan show MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 107 BCM.0> mir dest add id=0x3c000000, mode=IngressEgress srcport=xe0 To display the mirror configurations: BCM.0> mir show BCM.0> mir dest show To remove the example mirror configuration: BCM.0> mir dest delete id=0x3c000000 mode=IngressEgress srcport=xe0 MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 108: Sfptool

    "-r" - enable or disable rate select for multi-speed SFP modules. "-t" - enable or disable the transmitter for a specific port. "-w" - modify SFP register values, for advanced debug only. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 109 20: ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ....30: ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ....[root@mc1600-c1 ~]# MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 110: Baseboard Management Controller (Bmc)

    Therefore, a generic SMART EC IPMI OEM command must follow General OEM Command Structure table shown next. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 111: Smart Ec Ipmi Oem Command Summary

    Get Chassis Address Info Table 5-14 OEM/Group 0x49 User 5.2.2.1.2 Power Management In addition to the standard IPMI Chassis Control command, the following OEM commands are created for a fine power control over the chassis. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 112: Table 5-5 Set Fru Instance Power State

    #PERST of the slot. Note: It depends on the hardware architecture whether a certain power state is supported. There might be states that are not supported by the hardware. Response Data Completion Code 0xae MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 113: Table 5-6 Get Fru Instance Power State

    0: power down 1: power up 2: reset Note: It depends on the hardware architecture whether a certain power state is supported. There might be states that are not supported by the hardware. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 114: 5.2.2.1.3 Chassis Power Policy

    DC input power gets recovered from an unexpected power loss event. An explicit power on command or button event is required to turn on the payload power. Response Data Completion Code 0xae MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 115: Table 5-8 Get Chassis Power Policy

    1: Bit 0 of this policy is ignored, and the payload power remains when the DC input power gets recovered from an unexpected power loss event. An explicit power on command or button event required to turn on the payload power. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 116: 5.2.2.1.4 Aggregated Temperature Sensors

    = (56 - 0) * (temperature - non- critical[t_sensor]) / (critical[t_sensor] - non-critical[t_sensor]) else if temperature < non-recoverable[t_sensor] aggtemp[t_sensor] = (63 - 56) * (temperature - critical[t_sensor]) / (non-recoverable[t_sensor] - critical[t_sensor]) else aggtemp[t_sensor] = 63 MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 117: Table 5-9 Set Aggregated Temperature Sensor

    0xFF: Aggregated Temperature Sensor disabled Other values [7]: invalid flag 0: temperature in [5:0] is valid 1: temperature in [5:0] is invalid [6]: write as 0 [5:0] aggregated temperature level Response Data Completion Code 0xae MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 118: 5.2.2.1.5 Fan Control

    Product ID, and the device revision. Such information may not be available if either the FRU does not provide the information or the FRU is in such a state that it cannot provide the information to the BMC. In either case, zeros are returned. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 119: Table 5-11 Get Fru Present State Version 0

    Write as 1 FRU Device ID Response Data Completion Code 0xae FRU Present State 0: unknown 1: not present 2: present Manufacturer ID IANA, LSB first Product ID, LSB first Device Revision MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 120: 5.2.2.1.7 Chassis Address Info

    [7:6]: write as 0 [5:0]: length of the address info data N Chassis Address Info 4:3+N If there is no address info, a C null string with data length 1 is returned. MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 121: Ami MegaracĀ® Web Gui

    The first time you connect to the web GUI, you may encounter the following page. If you see this Insecure Connection page, you must add an exception to your web browser to continue to the login page Figure 5-3 Insecure Connection Page - MegaRAC Web GUI MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 122: 5.2.3.0.2 Login Page

    5.2.3.0.3 MegaRAC Dashboard Once you have successfully logged in, the dashboard is displayed. From the dashboard, you can traverse through the GUI menus to query and manage the system Figure 5-5 MegaRAC Dashboard MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 123: Related Documentation

    SMART EC Documentation Document Title Publication Number MC1600 Series Extreme Edge Server Data Sheet MC1600 Series DS MC1600 Extreme Edge Server Safety Notes Summary 6806870A04 MC1600 Extreme Edge Server Quick Start Guide 6806870A03 MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 124 Related Documentation Related Documentation MC1600 Extreme Edge Server Installation and Use (6806870A02B)
  • Page 126 © 2020 SMART Embedded Computing™, Inc. All Rights Reserved. The stylized “S” and “SMART” is a registered trademark of SMART Modular Technologies, Inc. and “SMART Embedded Computing” and the SMART Embedded Computing logo are trademarks of SMART Modular Technologies, Inc. All other names and logos...

Table of Contents