Fundamental safety instructions

2.1

General safety instructions

Electric shock and danger to life due to other energy sources
Touching live components can result in death or severe injury.
• Only work on electrical devices when you are qualified for this job.
• Always observe the country-specific safety rules.
Generally, the following steps apply when establishing safety:
1. Prepare for disconnection. Notify all those who will be affected by the procedure.
2. Isolate the drive system from the power supply and take measures to prevent it being
3. Wait until the discharge time specified on the warning labels has elapsed.
4. Check that there is no voltage between any of the power connections, and between any of
5. Check whether the existing auxiliary supply circuits are de-energized.
6. Ensure that the motors cannot move.
7. Identify all other dangerous energy sources, e.g. compressed air, hydraulic systems, or
8. Check that the correct drive system is completely locked.
After you have completed the work, restore the operational readiness in the inverse sequence.
Risk of electric shock and fire from supply networks with an excessively high impedance
Excessively low short-circuit currents can lead to the protective devices not tripping or tripping
too late, and thus causing electric shock or a fire.
• In the case of a conductor-conductor or conductor-ground short-circuit, ensure that the
• You must use an additional residual-current device (RCD) if a conductor-ground short circuit
AT40 and ATD400V for elevators
System Manual, 06/2022, A5E42192709-AH
WARNING
switched back on again.
the power connections and the protective conductor connection.
water. Switch the energy sources to a safe state.
WARNING
short-circuit current at the point where the converter is connected to the line supply at least
meets the minimum requirements for the response of the protective device used.
does not reach the short-circuit current required for the protective device to respond. The
required short-circuit current can be too low, especially for TT supply systems.