The items that can be set are as follows.
f [SLOT2], [SLOT3]
(Factory setting: [SLOT2])
[BATTERY]
[DC IN SOURCE]
Sets the type of external power supply to input to the <DC IN> terminal.
The items that can be set are as follows.
[DC POWER SUPPLY]
[BATTERY]
(Factory setting: [DC POWER SUPPLY])
[DC IN BATTERY]
[FULL VOLT]
[NEAR END VOLT]
[END VOLT]
[ONBOARD BATTERY]
[BATTERY SEL]
[FULL VOLT]
[NEAR END VOLT]
[END VOLT]
[NEAR END INFO]
[END INFO]
[GENLOCK]
[GENLOCK]
Switches the synchronization signal of the camera.
[INT]
[GL IN]
(Factory setting: [INT])
[H PHASE COARSE]
Performs coarse adjustment to match horizontal synchronization phase when building a system.
Chapter 4 Operation — Menu settings
Select when connecting the AC adaptor.
Select when connecting the battery.
Voltage to display full/near end/end remaining capacity can be set in the [OTHERS] menu → [BATTERY] → [DC IN
BATTERY].
Sets the voltage to display full remaining capacity when inputting an external battery from the <DC IN> terminal.
The items that can be set are as follows.
f [13.0V] ... [17.0V] (0.1 V steps)
(Factory setting: [15.5V])
Sets the voltage to display near end remaining capacity when inputting an external battery from the <DC IN> terminal.
The items that can be set are as follows.
f [11.1V] ... [15.0V] (0.1 V steps)
(Factory setting: [13.2V])
Sets the voltage to display end remaining capacity when inputting an external battery from the <DC IN> terminal.
The items that can be set are as follows.
f [11.0V] ... [14.9V] (0.1 V steps)
(Factory setting: [12.5V])
Select according to the used battery.
When set to [DIONIC], [HYTRON/TITON], [ENDURA], or [PAG], remaining capacity is detected and the warning is displayed
according to the [NEAR END INFO] or the [END INFO] setting.
The remaining capacity is detected by the voltage level when set to [other].
When there is no remaining capacity information, the remaining capacity is detected by the voltage level.
The items that can be set are as follows.
f [DIONIC], [HYTRON/TITON], [ENDURA], [PAG], [other]
(Factory setting: [DIONIC])
Sets the voltage to display full remaining capacity when the battery remaining capacity is detected by the voltage level.
The items that can be set are as follows.
f [13.0V] ... [17.0V] (0.1 V steps)
(Factory setting: [15.5V])
Sets the voltage to display near end remaining capacity when the battery remaining capacity is detected by the voltage level.
The items that can be set are as follows.
f [11.1V] ... [15.0V] (0.1 V steps)
(Factory setting: [13.2V])
Sets the voltage to display end remaining capacity when the battery remaining capacity is detected by the voltage level.
The items that can be set are as follows.
f [11.0V] ... [14.9V] (0.1 V steps)
(Factory setting: [12.5V])
Sets the percent value of the near end remaining capacity when the remaining capacity information is acquired from the
battery.
The items that can be set are as follows.
f [4%], [5%], [6%], [7%], [8%], [9%], [10%], [12%], [14%], [16%], [18%], [20%]
(Factory setting: [5%])
Sets the percent value of the end remaining capacity when the remaining capacity information is acquired from the battery.
The items that can be set are as follows.
f [1%] ... [10%] (1% steps)
(Factory setting: [1%])
Synchronizes to the internal standard signal regardless of the standard signal input to the <GENLOCK IN> terminal.
Synchronizes to the standard signal input to the <GENLOCK IN> terminal.
– 104 –