8.3 Operation via the AOP30 operator panel
8.3.1.2

Buttons of the AOP30

Functions of the control keys
See also
Control settings (Page 117)
Inhibit functions (Page 120)
8.3.1.3

Basic operation of the AOP 30

The menu structure
Operation of the AOP 30 is menu-driven.
To make it easier to find a menu, the following figure shows the menu structure.
110
Calls the main menu of the AOP30.
Calls the "inhibit functions" menu.
Numeric keys for direct entry of values.
Switches between remote and local mode. In local operation, the LED
illuminates.
On/off
If no operator inhibit is activated, then the "On" button in local operation is
always active. The "Off" button is only active in local operation, and in the
factory setting acts as "OFF1".
Counterclockwise-clockwise switchover
The button is only active in local mode.
JOG (Jogging)
The key is only in effect in local mode in "Ready to switch on" status (not
when "operating"). The system is accelerated to the setpoint speed.
Setpoint "increase" and setpoint "decrease".
You can enter the setpoint using these buttons. Alternatively, you can
enter the setpoint using the alphanumeric keys. Using the numeric key‐
pad, any speed ranging between the maximum and minimum speed can
be entered.
Function keys.
These keys have different functions depending on the menu. The respec‐
tive function appears in plain text above the key.
SINAMICS GM150 6SL3835-2LN44-2AA0