XLi responds:
F6<S><STATE><CR><LF>
where:
= ASCII character F
F
= function number
6
= ASCII space character (one or more)
<S>
<STATE> = ENABLE or DISABLE
= carriage return character
<CR>
= line feed character
<LF>
For example, to display the Keypad Lock status, send:
F6<CR>
XLi responds:
F6 DISABLE<CR><LF>
To enable Keypad Lock, send the following string:
F6 ENABLE<CR>
XLi responds:
OK<CR><LF>
To disable Keypad Lock, send the following string:
F6 DISABLE<CR>
XLi responds:
OK<CR><LF>

F8 - Continuous Time Once-per-Second

The function F8 commands and outputs are available only on the command line interface (through the
serial and network ports). They are not available through the keypad display or web interfaces.
Function F8 outputs the time-of-year once per second, conditionally followed by a time quality character.
F8 is affected by the following functions:
F2 – 12/24 Hour Format (page 39)