faultPrimaryRefClkOBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a primary reference clock fault occurred since the fault
latch was cleared."
::= { systemFaultHistory 3 }
faultSecondaryRefClk OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a secondary reference clock lock fault occurred since the
fault latch was cleared."
::= { systemFaultHistory 4 }
faultIrig OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if an IRIG lock fault occurred since the fault
latch was cleared."
::= { systemFaultHistory 5 }
faultAuxRef OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if an auxiliary reference clock fault occurred since
the fault latch was cleared."
::= { systemFaultHistory 6 }
faultPrimaryPower OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a primary power fault occurred since the fault
latch was cleared."
::= { systemFaultHistory 7 }
faultSecondaryPower OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a secondary power fault occurred since the fault
latch was cleared."
::= { systemFaultHistory 8 }
XLi IEEE 1588 Clock
997-01510-03, Rev. C, 12/12/2006
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
2
1
5
S
S
S
S
171

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xli ieee 1588 clock

Table of Contents