F100 K I L L - Reboot - Symmetricom XLi IEEE 1588 User Manual

Symmetricom xli ieee 1588 clock user guide
Table of Contents

Advertisement

S
S
S
S
S
S
S
S
S
Units are shipped to the customer with no jumper installed. The jumper is used by Symmetricom
technicians to test and configure the unit. With this jumper installed, the operation and integrity of the XLi
are compromised.
Warning:
Please do not run the XLi with the jumper, unless specifically directed to do so by a
qualified Symmetricom technician.
To test the state of the factory mode jumper:
F100<S>J<CR>
where:
= ASCII character F
F
= unit function number
100
= space
<S>
= specify User Name command
J
<CR> = input line terminator
The XLi responds:
F100 J FACTORY MODE=1<CR><LF>
or
F100 J FACTORY MODE=0<CR><LF>
F100 K I L L – Reboot
Use function F100 K I L L to reboot the unit. Use F100 K I L L after upgrading the system firmware.
K I L L is a case-sensitive command. When entering this command, use all capital letters and put
spaces between each letter.
To reboot the unit, enter:
F100 K<S>I<S>L<S>L<CR>
For example:
F100 K I L L<CR>
XLi responds:
OK <CR><LF>
RESETING THE UNIT<CR><LF>
PLEASE WAIT...<CR><LF>