faultRbOsc OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a rubidium oscillator fault occurred since the fault
latch was cleared."
::= { systemFaultHistory 9 }
faultDac OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a digital to audio converter fault has occurred since the
fault latch was cleared."
::= { systemFaultHistory 10 }
faultFirstTimeLock OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if the system clock has failed to lock since power on and the
latched faults have not been cleared."
::= { systemFaultHistory 11 }
faultTimeError OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a time error fault occurred since the fault latch was
cleared."
::= { systemFaultHistory 12 }
faultTimeout OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a timeout fault occurred since the fault latch was
cleared."
::= { systemFaultHistory 13 }
faultNtp OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if NTP was in an alarm since the fault latch was cleared."
::= { systemFaultHistory 14 }
statusClock OBJECT-TYPE
172
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
XLi IEEE 1588 Clock
997-01510-03, Rev. C, 12/12/2006
S
S
S
S

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xli ieee 1588 clock

Table of Contents