Standard 110 VAC Power Supply

The XLi's internal fault detector can monitor the three output voltages from the primary and the
secondary power supplies. With the Primary Power or Secondary Power indicators in F73 enabled, a
10% decrease in any of the output voltages triggers an alarm. See
page
69.
Warning: Ensure that a disconnect device, such as a switch, with the appropriate voltage/current rating,
is provided when operating/installing the XLi.
Warning: Prior to servicing the interior of a unit with dual power supplies, remove both power cords.
Input connector:
Input voltage range:
Input frequency range:
Isolation, ground:
Isolation:
Output Specifications:
Fan:
6
S
S
S
S
S
S
S
S
S
IEC 320 type
Universal, 90 – 260 VAC and 110 – 370 VDC
47 Hz – 440 Hz
For 110-370 VDC operation, the input is fully floating. Either
input polarity may be strapped to chassis ground.
1,500 VAC, input to ground
+5.2 V (5.0 to 5.4 V), 25 watts, 0 to 5 amps
+12 V (11.4 to 12.6 V), 45 watts, 0 to 3.8 amps
-12 V (–11.4 to –12.6 V) 32 watts, 0 to 2.7 amps
Exhaust 3-6CFM
S
S
S
S
S
S
S
S
S
"F73 – Alarm Control / Status" on
S
S
S
S
S
S
S
S
S
XLi IEEE 1588 Clock
997-01510-03, Rev. C, 12/12/2006