maskFirstTimeLock OBJECT-TYPE
SYNTAX FaultMaskType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If enabled, an alarm can be triggered when the locking status of the
clock since power on changes."
::= { systemFaultConfigMasks 11 }
maskTimeError OBJECT-TYPE
SYNTAX FaultMaskType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If enabled, an alarm can be triggered when the time error threshold
is reached."
::= { systemFaultConfigMasks 12 }
maskTimeout OBJECT-TYPE
SYNTAX FaultMaskType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If enabled, an alarm can be triggered when the timeout threshold is
reached."
::= { systemFaultConfigMasks 13 }
maskNtp OBJECT-TYPE
SYNTAX FaultMaskType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If enabled, an alarm will be triggered when NTP is in alarm."
::= { systemFaultConfigMasks 14 }
faultPllSynthesizerOBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a PLL synthesizer fault occurred since the fault
latch was cleared."
::= { systemFaultHistory 1 }
faultLpnPllOBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a LPN PLL fault occurred since the fault
latch was cleared."
::= { systemFaultHistory 2 }
170
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
XLi IEEE 1588 Clock
997-01510-03, Rev. C, 12/12/2006
S
S
S
S

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xli ieee 1588 clock

Table of Contents