Connecting The Earthing - Auerswald COMpact 5200 Instruction Manual

Pbx for internet/isdn/analogue telephony
Hide thumbs Also See for COMpact 5200:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 31
Commissioning (COMpact 5200)
– Grounding conductor (potential compensation bar of the house installation or
protective earth conductor)
1.
Mark and drill the two upper mounting holes at a distance of 232 mm and insert dowels
into the holes.
Note: Also note the casing dimensions 334 mm x 331 mm x 94.5 mm. There should
be a distance of at least 60 mm between the upper mounting bores and any parts
above them. A drilling template can be found on the Internet.
2.
Screw in the two upper screws far enough so that the screw head is about 5 mm away
from the wall.
3.
Mount the PBX on the screws, then slide the PBX on the wall downwards until the screws
hit the stopper.
4.
Place a mark where the third mounting hole is to be drilled into the wall.
5.
Remove the PBX from the wall.
6.
Drill the mounting hole and insert a dowel into the hole.
7.
Mount the PBX on the screws again, then slide the PBX on the wall downwards until the
screws hit the stopper.
8.
Secure the PBX by tightening the third screw.

Connecting the Earthing

Warning: Touching voltage-carrying conductors or telephone connections can cause
life-threatening electric shocks. The PBX contains hazardous voltages, even outside
of the power supply unit (for instance ringer voltages). Work on active, contact-
hazardous parts is only permitted after creating a voltage-free state. Working close to
active parts is only permitted if these parts are voltage-free or are protected against
direct contact.
• Disconnect terminal devices from the PBX. No terminal devices should be
connected during the installation of the earthing. Connected terminals may feed-in
currents which might cause electrical shocks.
• Pull out the PBX's power plug. Also disconnect the device from additional power
sources (e. g. UPS, if installed).
• Wait at least 3 minutes for the discharge of any capacitor in the device after
disconnecting it from the main power supply.
• Only a fixed installation is allowed for the connection of the earthing terminal of the
PBX to the potential compensation bar of the house installation or the protective
earth conductor. Plug connections are not allowed.
Requirements:
Screw driver
Connecting cable with at least 2.5 mm
Proper earth connection close to the installation site (equipotential bonding rail of the
house installation or protective earth conductor)
42
²
conductor cross-section
COMpact 5200/5200R/5500R - Instructions V03 03/2019

Advertisement

Table of Contents
loading

This manual is also suitable for:

Compact 5200rCompact 5500r

Table of Contents