Reference clock ID: 3.0.1.31
Nominal frequency: 64.0000 Hz
Actual frequency: 64.0000 Hz
Clock precision: 2^7
Clock offset: 0.0000 ms
Root delay: 31.00 ms
Root dispersion: 8.31 ms
Peer dispersion: 34.30 ms
Reference time: 16:01:51.713 UTC Sep 19 2005 (C6D95F6F.B6872B02)
# View the NTP session information of Device A, which shows that an association has been set up Device
A and Device C.
[DeviceA-Vlan-interface2] display ntp-service sessions
source
reference
**************************************************************************
[1234] 3.0.1.31
127.127.1.0
note: 1 source(master),2 source(peer),3 selected,4 candidate,5 configured
Total associations :
# NTP authentication is enabled on Device B, but not enabled on Device C. Therefore, Device B cannot
synchronize its local clock to that of Device C.
[DeviceB-Vlan-interface2] display ntp-service status
Clock status: unsynchronized
Clock stratum: 16
Reference clock ID: none
Nominal frequency: 100.0000 Hz
Actual frequency: 100.0000 Hz
Clock precision: 2^18
Clock offset: 0.0000 ms
Root delay: 0.00 ms
Root dispersion: 0.00 ms
Peer dispersion: 0.00 ms
Reference time: 00:00:00.000 UTC Jan 1 1900(00000000.00000000)
# Enable NTP authentication Device C. Configure an NTP authentication key, with the key ID of 88 and
key value of 123456. Specify the key as a trusted key.
[DeviceC] ntp-service authentication enable
[DeviceC] ntp-service authentication-keyid 88 authentication-mode md5 123456
[DeviceC] ntp-service reliable authentication-keyid 88
# Specify Device C as an NTP broadcast server, and associate the key 88 with Device C.
[DeviceC] interface vlan-interface 2
[DeviceC-Vlan-interface2] ntp-service broadcast-server authentication-keyid 88
# After NTP authentication is enabled on Device C, Device B can synchronizes its local clock to that of
Device C. View NTP service status information on Device B, you can see that Device B has been
synchronized to Device C, and the clock stratum level of Device B is 4, while that of Device C is 3.
[DeviceB-Vlan-interface2] display ntp-service status
Clock status: synchronized
Clock stratum: 4
Reference clock ID: 3.0.1.31
Nominal frequency: 64.0000 Hz
stra
reach
3
254
1
32
poll
now
offset
64
62
-16.0
delay
disper
32.0
16.6