H3C S5560S-SI Installation Manual

H3C S5560S-SI Installation Manual

Hide thumbs Also See for S5560S-SI:
Table of Contents

Advertisement

H3C S5560S-SI & S5500V3-SI &
S5130S-SI[LI]
S5120V2-SI[LI] &
&
S5110V2-SI & S5000V3-EI &
S3100V3-SI Switch Series

Installation Guide

H3C S5560S-SI Switch Series
H3C S5500V3-SI Switch Series
H3C S5130S-SI Switch Series
H3C S5130S-LI Switch Series
H3C S5120V2-SI Switch Series
H3C S5120V2-LI Switch Series
H3C S5110V2-SI Switch Series
H3C S5000V3-EI Switch Series
H3C S3100V3-SI Switch Series
New H3C Technologies Co., Ltd.
http://www.h3c.com
Document version: 6W104-20190731

Advertisement

Table of Contents
loading

Summary of Contents for H3C S5560S-SI

  • Page 1: Installation Guide

    H3C S5560S-SI & S5500V3-SI & S5130S-SI[LI] S5120V2-SI[LI] & & S5110V2-SI & S5000V3-EI & S3100V3-SI Switch Series Installation Guide H3C S5560S-SI Switch Series H3C S5500V3-SI Switch Series H3C S5130S-SI Switch Series H3C S5130S-LI Switch Series H3C S5120V2-SI Switch Series H3C S5120V2-LI Switch Series...
  • Page 2 The information in this document is subject to change without notice. All contents in this document, including statements, information, and recommendations, are believed to be accurate, but they are presented without warranty of any kind, express or implied. H3C shall not be liable for technical or editorial errors or omissions contained herein.
  • Page 3 Preface The installation guide describes the appearance, installation, power-on, maintenance, and troubleshooting of the H3C S5560S-SI, S5130S-SI, S5130S-LI, S5120V2-SI, S5120V2-LI, S5110V2-SI, S5000V3-EI, and S3100V3-SI Switch Series. This preface includes the following topics about the documentation: • Audience. • Conventions. •...
  • Page 4 Convention Description Multi-level menus are separated by angle brackets. For example, File > Create > > Folder. Symbols Convention Description An alert that calls attention to important information that if not understood or followed WARNING! can result in personal injury. An alert that calls attention to important information that if not understood or followed CAUTION: can result in data loss, data corruption, or damage to hardware or software.
  • Page 5: Documentation Feedback

    It is normal that the port numbers, sample output, screenshots, and other information in the examples differ from what you have on your device. Documentation feedback You can e-mail your comments about product documentation to info@h3c.com. We appreciate your comments.
  • Page 6: Table Of Contents

    Contents Preparing for installation ····································································1 Safety recommendations ··············································································································· 3 Examining the installation site········································································································· 3 Temperature/humidity ············································································································ 4 Cleanliness ·························································································································· 4 EMI ···································································································································· 4 Laser safety ························································································································· 5 Installation tools ··························································································································· 5 Installing the switch ··········································································6 Installing the switch in a 19-inch rack ······························································································· 6 Mounting brackets ·················································································································...
  • Page 7 S3100V3-10TP-PWR-SI ······································································································· 65 S3100V3-20TP-PWR-SI ······································································································· 65 S3100V3-28TP-PWR-SI ······································································································· 66 Technical specifications ·············································································································· 67 S5560S-SI switch series ······································································································· 67 S5130S-SI & S5130S-LI switch series ····················································································· 69 S5120V2-SI & S5120V2-LI switch series ················································································· 71 S5110V2-SI switch series ····································································································· 74 S5000V3-EI switch series ····································································································· 75 S5500V3-SI switch series ·····································································································...
  • Page 8 10/100/1000BASE-T autosensing Ethernet port ········································································ 83 SFP port ···························································································································· 83 SFP+ port ·························································································································· 86 Combo interface ·················································································································· 88 LEDs ······································································································································· 88 System status LED ·············································································································· 88 Management Ethernet port LED ····························································································· 89 Power module status LED ····································································································· 89 RPS status LED ·················································································································· 89 Mode LED (MODE)··············································································································...
  • Page 9: Preparing For Installation

    Preparing for installation This document provides an installation guide for the following switch series: • S5560S-SI switch series • S5130S-SI switch series • S5130S-LI switch series • S5120V2-SI switch series • S5120V2-LI switch series • S5110V2-SI switch series • S5000V3-EI switch series •...
  • Page 10 Switch series Model Product code LS-5120V2-10P-LI S5120V2-10P-LI LS-5120V2-10P-LI-GL LS-5120V2-20P-LI S5120V2-20P-LI LS-5120V2-20P-LI-GL Non-PoE models LS-5120V2-28P-LI S5120V2-28P-LI LS-5120V2-28P-LI-GL LS-5120V2-52P-LI S5120V2-52P-LI LS-5120V2-52P-LI-GL S5120V2-LI LS-5120V2-10P-PWR-LI switch series S5120V2-10P-PWR-LI LS-5120V2-10P-PWR-LI-GL LS-5120V2-28P-PWR-LI S5120V2-28P-PWR-LI LS-5120V2-28P-PWR-LI-GL PoE models LS-5120V2-28P-HPWR-LI S5120V2-28P-HPWR-LI LS-5120V2-28P-HPWR-LI-GL LS-5120V2-52P-PWR-LI S5120V2-52P-PWR-LI LS-5120V2-52P-PWR-LI-GL S5120V2-12TP-HPWR-LI LS-5120V2-12TP-HPWR-LI S5110V2-28P-SI LS-5110V2-28P-SI S5110V2-SI Non-PoE switch series...
  • Page 11: Safety Recommendations

    Switch series Model Product code S3100V3-10TP-SI LS-3100V3-10TP-SI S3100V3-18TP-SI LS-3100V3-18TP-SI Non-PoE models S3100V3-28TP-SI LS-3100V3-28TP-SI S3100V3-SI S3100V3-52TP-SI LS-3100V3-52TP-SI switch series S3100V3-10TP-PWR-SI LS-3100V3-10TP-PWR-SI S3100V3-20TP-PWR-SI LS-3100V3-20TP-PWR-SI PoE models S3100V3-28TP-PWR-SI LS-3100V3-28TP-PWR-SI Safety recommendations To avoid equipment damage or bodily injury, read the following safety recommendations before installation.
  • Page 12: Temperature/Humidity

    Temperature/humidity Maintain temperature and humidity in the equipment room as described in "Technical specifications." • Lasting high relative humidity can cause poor insulation, electricity leakage, mechanical property change of materials, and metal corrosion. • Lasting low relative humidity can cause washer contraction and ESD and cause problems including loose mounting screws and circuit failure.
  • Page 13: Laser Safety

    • Keep the switch far away from radio transmitting stations, radar stations, and high-frequency devices to make sure the EMI levels do not exceed the compliant range. • Use electromagnetic shielding when necessary. For example, use shielded interface cables. • To prevent signal ports from getting damaged by overvoltage or overcurrent caused by lightning strikes, only route interface cables indoors.
  • Page 14: Installing The Switch

    CAUTION: Keep the tamper-proof seal on a mounting screw on the chassis cover intact, and if you want to open the chassis, contact H3C for permission. Otherwise, H3C shall not be liable for any consequence. Figure 1 Hardware installation flow...
  • Page 15 Applicable mounting Switch model Views brackets S5560S-28S-SI S5560S-52S-SI S5130S-28S-SI S5130S-52S-SI S5130S-28S-LI S5130S-52S-LI S5130S-28S-PWR-LI S5130S-28S-HPWR-LI S5130S-52S-PWR-LI S5120V2-28P-SI S5120V2-52P-SI S5120V2-28P-LI S5120V2-52P-LI S5120V2-28P-PWR-LI S5120V2-28P-HPWR-LI S5120V2-52P-PWR-LI S5110V2-28P-SI S5110V2-52P-SI S5024PV3-EI S5048PV3-EI S5024PV3-EI-PWR S5024PV3-EI-HPWR S5048PV3-EI-PWR S5024FV3-EI S5500V3-24P-SI S5500V3-48P-SI S3100V3-28TP-SI S3100V3-52TP-SI S3100V3-28TP-PWR-SI S5560S-28F-SI S5560S-28DP-SI Mounting brackets B (provided) See B in Figure S5130S-28F-SI...
  • Page 16: Attaching The Mounting Brackets To The Switch

    Figure 2 Mounting brackets (1) Screw hole for attaching the bracket to the switch (2 ) Screw hole for attaching the bracket to the rack post Attaching the mounting brackets to the switch Determine the installation position for the mounting brackets. The S5560S-28F-SI, S5560S-28DP-SI, and S5130S-28F-SI switches each provide two ...
  • Page 17 Figure 3 Attaching mounting bracket A (S5120V2-28P-HPWR-LI switch) Figure 4 Attaching mounting bracket B (mounting position near the port side, S5560S-28F-SI switch) Figure 5 Attaching mounting bracket B (mounting position near the power module side, S5560S-28F-SI switch)
  • Page 18: Rack-Mounting The Switch

    Figure 6 Attaching mounting bracket C (S5120V2-20P-LI switch) Figure 7 Attaching mounting bracket D (S5120V2-10P-LI switch) Rack-mounting the switch This task requires two people. To mount the switch in the rack: Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded. Verify that the mounting brackets have been securely attached to the switch chassis.
  • Page 19 Figure 8 Mounting the switch in a rack (S5120V2-28P-HPWR-LI switch) Figure 9 Mounting the switch in a rack (mounting brackets installed near the port side, S5560S-28F-SI switch) Figure 10 Mounting the switch in a rack (mounting brackets installed near the power module side, S5560S-28F-SI switch)
  • Page 20: Mounting The Switch On A Workbench

    Figure 11 Mounting the switch in a rack (S5120V2-10P-PWR-LI switch) Figure 12 Mounting the switch in a rack (S5120V2-10P-LI) Mounting the switch on a workbench IMPORTANT: • Ensure 10 cm (3.9 in) of clearance around the chassis for heat dissipation. •...
  • Page 21: Mounting The Switch On A Wall

    Mounting the switch on a wall CAUTION: • Before drilling holes in a wall, make sure no electrical lines exist in the wall. • Leave a minimum clearance of 10 mm (0.39 in) around the chassis for heat dissipation. The S5120V2-SI switch, S5120V2-LI switch, S5000V3-EI switch series, and S3100V3-SI switch series support wall mounting.
  • Page 22 Figure 14 Installing the switch on a wall (1) Drill two holes with a diameter of 6 mm (0.24 in) and a depth of 25 mm (0.98 in) at the marked locations. Hammer the screw anchors into the wall and use a Phillips screwdriver to fasten the screw into the screw anchor.
  • Page 23: Grounding The Switch

    Grounding the switch WARNING! Correctly connecting the switch grounding cable is crucial to lightning protection and EMI protection. The power input end of the switch has a noise filter, whose central ground is directly connected to the chassis to form the chassis ground (commonly known as PGND). You must securely connect this chassis ground to the earth to minimize the potential for system damage, maximize the safety at the site, and minimize EMI susceptibility of the system.
  • Page 24: Grounding The Switch With A Grounding Conductor Buried In The Earth Ground

    Figure 17 Attaching the grounding cable to the grounding hole of the switch (S5120V2-28P-HPWR-LI switch) (1) Grounding screw (2) Ring terminal (3) Grounding sign (4) Grounding hole (5) Grounding cable Connect the other end of the grounding cable to the grounding strip. a.
  • Page 25: Grounding The Switch By Using The Pe Wire Of The Ac Power Cord

    Weld the yellow-green grounding cable to the angel iron or steel tube and treat the joint for corrosion protection. Figure 19 Grounding the switch by burying the grounding conductor into the earth ground (1) Grounding screw (2) Grounding cable (3) Earth (4) Joint (5) Grounding conductor (6) Chassis rear panel...
  • Page 26: Installing A Power Module

    power module slot 2 installed with a filler panel. You can install another PSR75-12A power module for the switch as required. For the specifications of the PSR75-12A power module, see Table Figure 20 Installation procedure Install the power Connect the power Turn on the circuit module cord...
  • Page 27: Removing A Power Module

    Figure 23 Installing a power module Removing a power module Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded. Remove the power cord from the power module. Use a Phillips screwdriver to loosen the captive screws on the power module until they are completely disengaged from the chassis.
  • Page 28: Connecting The Ac Power Cord For The Fixed Ac Power Module

    Switch model Available power source Connection procedure reference Connecting the DC power cord for the RPS (RPS1600-A) fixed DC power module • S5560S-28F-SI AC power source Connecting the power cord for a • S5560S-28DP-SI 240 VDC high-voltage PSR75-12A power module power source S5130S-28F-SI Connecting the AC power cord for the...
  • Page 29: Connecting The Dc Power Cord For The Fixed Dc Power Module

    CAUTION: To connect to an H3C recommended RPS, use a power cord compatible with the RPS. To connect the DC power cord for the fixed DC power module: Correctly orient the DC power cord connector and insert the connector into the power receptacle on the power module.
  • Page 30: Verifying The Installation

    Figure 27 Connecting the power cord for a PSR75-12A power module (1) Figure 28 Connecting the power cord for a PSR75-12A power module (2) Verifying the installation After you complete the installation, verify the following items: • There is enough space for heat dissipation around the switch, and the rack or workbench is stable.
  • Page 31: Accessing The Switch For The First Time

    Accessing the switch for the first time You can use the following methods to access and manage the switch for the first time: • Managing the switch from the GUI • Managing the switch from the CLI Managing the switch from the GUI Only the S5000V3-EI switch supports GUI management.
  • Page 32: Managing The Switch From The Cli

    Managing the switch from the CLI Setting up the configuration environment You can access the S5560S-28S-SI switch, S5560S-52S-SI switch, S5560S-28F-SI switch, S5560S-28DP-SI switch, S5130S-SI switch series, S5500V3-SI switch series, and S5130S-LI switches series from the serial console port or the micro USB console port. If you connect both ports, only the micro USB console port is available.
  • Page 33 Connect the micro USB connector to the micro USB console port on the switch. Click the following link, or copy it to the address bar on the browser to download the USB console driver. http://www.h3c.com.hk/Technical_Support___Documents/Software_Download/Other_Product /USB_Console/USB_Console/ Select a driver program according to the operating system you use: XR21V1410_XR21B1411_Windows_Ver1840_x86_Installer.EXE—32-bit operating...
  • Page 34 Figure 31 Device Driver Installation Wizard Click Continue Anyway if the following dialog box appears. Figure 32 Software Installation Click Finish.
  • Page 35: Starting The Switch

    Figure 33 Completing the device driver installation wizard Setting terminal parameters To configure and manage the switch through the console port, you must run a terminal emulator program, HyperTerminal or PuTTY, on your configuration terminal. For more information about the terminal emulator programs, see the user guides for these programs.
  • Page 36 versions. For more information about Boot ROM menu options, see the software-matching release notes for the device. After the startup completes, you can access the CLI to configure the switch. For more information about the configuration commands and CLI, see the configuration guides and command references for the switch series.
  • Page 37: Setting Up An Irf Fabric

    Setting up an IRF fabric You can use H3C IRF technology to connect and virtualize multiple switches into a large virtual switch called an "IRF fabric" for flattened network topology, and high availability, scalability, and manageability. The switch can set up an IRF fabric only with switches from the same switch series.
  • Page 38: Planning Irf Fabric Setup

    Step Description "Installing the switch in a 19-inch rack" or "Mounting the switch Install IRF member switches. on a workbench." Connect grounding cables and "Grounding the switch," "Installing and removing a power power cords. module," and "Connecting the power cord." Power on the switches.
  • Page 39 When connecting two neighboring IRF member switches, you must connect the physical ports of IRF-port 1 on one switch to the physical ports of IRF-port 2 on the other switch. The switch can form an IRF fabric only with switches from the same switch series. For the physical ports that can be used for IRF connections on each switch model and the restrictions for using the ports, see Table...
  • Page 40: Identifying Irf Physical Ports On The Member Switches

    Identifying IRF physical ports on the member switches IMPORTANT: For the switch that provides 10-GE SFP+ ports, only the SFP+ ports can be used as IRF physical ports when the switch runs Release 611x and Release 612x. Identify the IRF physical ports on the member switches according to your topology and connection scheme.
  • Page 41: Planning The Cabling Scheme

    If the IRF member switches are all in one equipment room, use twisted pair cables or SFP/SFP+ cables. The following subsections describe several H3C recommended IRF connection schemes by using SFP cables and SFP transceiver modules and fibers. All these schemes use a ring topology.
  • Page 42: Configuring Basic Irf Settings

    Use twisted pair cables, SFP/SFP+ cables, or SFP/SFP+ transceiver modules and fibers to connect the IRF member switches as planned. Wear an ESD wrist strap when you connect twisted pair cables, SFP/SFP+ cables, or SFP/SFP+ transceiver modules and fibers. For how to connect them, see H3C Transceiver Modules and Network Cables Installation Guide.
  • Page 43: Verifying The Irf Fabric Setup

    Verifying the IRF fabric setup To verify the basic functionality of the IRF fabric after you finish configuring basic IRF settings and connecting IRF ports: Log in to the IRF fabric through the console port of any member switch. Create a Layer 3 interface, assign it an IP address, and make sure the IRF fabric and the remote network management station can reach each other.
  • Page 44: Maintenance And Troubleshooting

    Verify that the operating temperature of the switch is in the acceptable range, and the power module has good ventilation. Over-temperature can cause the power module to stop working and enter protection state. If the issue persists, contact H3C Support. Input failure on an RPS-powered switch Symptom...
  • Page 45: Input Failure On An Rps And Ac-Powered Switch

    Verify that the operating temperature of the switch is in the acceptable range, and the power module has good ventilation. Over-temperature can cause the power module to stop working and enter protection state. If the issue persists, contact H3C Support. Input failure on an RPS and AC-powered switch Symptom 1 The system status LED on the RPS and AC-powered switch is off.
  • Page 46: Fan Tray Failure

    Fan tray failure Symptom The system status LED on the switch indicates a fan tray failure. Solution When a fan tray issue occurs, contact H3C Support. Configuration terminal issues No display on the configuration terminal Symptom The configuration terminal does not have display when the switch is powered on.
  • Page 47: Garbled Display On The Configuration Terminal

    The configuration terminal displays garbled text. Solution To resolve the issue: Verify that the following settings are configured for the terminal: Baud rate—9600.  Data bits—8.  Parity—None.  Stop bits—1.  Flow control—None.  If the issue persists, contact H3C Support.
  • Page 48: Appendix A Chassis Views And Technical Specifications

    Appendix A Chassis views and technical specifications Chassis views S5560S-28P-SI Figure 40 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP port LED (4) System status LED (SYS) (5) Console port (CONSOLE) (6) SFP port Figure 41 Rear panel (1) Grounding screw (2) AC-input power receptacle...
  • Page 49: S5560S-52P-Si

    S5560S-52P-SI Figure 42 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) Console port (CONSOLE) (4) SFP port LED (5) System status LED (SYS) (6) SFP port Figure 43 Rear panel (1) Grounding screw (2) AC-input power receptacle S5560S-28S-SI Figure 44 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port...
  • Page 50: S5560S-52S-Si

    Figure 45 Rear panel (1) Grounding screw (2) AC-input power receptacle S5560S-52S-SI Figure 46 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) Console port (CONSOLE) (4) Micro USB console port (5) SFP+ port LED (6) System status LED (SYS) (7) SFP+ port Figure 47 Rear panel...
  • Page 51: S5560S-28F-Si

    S5560S-28F-SI Figure 48 Front panel (1) SFP port (2) SFP port LED (3) 10/100/1000BASE-T autosensing Ethernet port (4) 10/100/1000BASE-T autosensing Ethernet port LED (5) Management Ethernet port (6) Console port (CONSOLE) (7) Micro USB console port (8) System status LED (SYS) (9) Power module 2 status LED (PWR2) (10) Power module 1 status LED (PWR1) (11) SFP+ port LED...
  • Page 52: S5560S-28Dp-Si

    S5560S-28DP-SI Figure 50 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) Management Ethernet port (4) Console port (CONSOLE) (5) Micro USB console port (6) Mode button (7) Mode LED (MODE) (8) USB port (9) System status LED (SYS) (10) SFP port (11) Power module 2 status LED (PWR2) (12) Power module 1 status LED (PWR1)
  • Page 53: S5130S-28S-Si & S5130S-28S-Li

    S5130S-28S-SI & S5130S-28S-LI Figure 52 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP+ port LED (4) System status LED (SYS) (5) Micro USB console port (6) Console port (CONSOLE) (7) SFP+ port Figure 53 Rear panel (1) Grounding screw (2) AC-input power receptacle S5130S-52S-SI &...
  • Page 54: S5130S-28F-Si

    Figure 55 Rear panel (1) Grounding screw (2) AC-input power receptacle S5130S-28F-SI Figure 56 Front panel (1) SFP port (2) SFP port LED (3) 10/100/1000BASE-T autosensing Ethernet port (4) 10/100/1000BASE-T autosensing Ethernet port LED (5) Management Ethernet port (6) Console port (CONSOLE) (7) Micro USB console port (8) System status LED (SYS) (9) Power module 2 status LED (PWR2)
  • Page 55: S5130S-28S-Pwr-Li

    S5130S-28S-PWR-LI Figure 58 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) Mode button (3) 10/100/1000BASE-T autosensing Ethernet port LED (4) SFP+ port LED (5) System status LED (SYS) (6) Mode LED (MODE) (7) Micro USB console port (8) Console port (CONSOLE) (9) SFP+ port Figure 59 Rear panel (1) Grounding screw...
  • Page 56: S5130S-52S-Pwr-Li

    Figure 61 Rear panel (1) Grounding screw (2) AC-input power receptacle (3) DC-input power receptacle S5130S-52S-PWR-LI Figure 62 Front panel 10 9 (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) Console port (CONSOLE) (4) Mode button (5) System status LED (SYS) (6) RPS status LED (RPS) (7) Mode LED (MODE)
  • Page 57: S5120V2-10P-Si & S5120V2-10P-Li

    S5120V2-10P-SI & S5120V2-10P-LI Figure 64 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP port LED (4) System status LED (SYS) (5) Console port (CONSOLE) (6) SFP port Figure 65 Rear panel (1) Grounding screw (2) AC-input power receptacle S5120V2-20P-LI Figure 66 Front panel...
  • Page 58: S5120V2-28P-Si & S5120V2-28P-Li

    Figure 67 Rear panel (1) AC-input power receptacle (2) Grounding screw S5120V2-28P-SI & S5120V2-28P-LI Figure 68 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP port LED (4) System status LED (SYS) (5) Console port (CONSOLE) (6) SFP port Figure 69 Rear panel (1) Grounding screw...
  • Page 59: S5120V2-52P-Si & S5120V2-52P-Li

    S5120V2-52P-SI & S5120V2-52P-LI Figure 70 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) Console port (CONSOLE) (4) SFP port LED (5) System status LED (SYS) (6) SFP port Figure 71 Rear panel (1) Grounding screw (2) AC-input power receptacle S5120V2-10P-PWR-LI Figure 72 Front panel...
  • Page 60: S5120V2-28P-Pwr-Li

    Figure 73 Rear panel (1) AC-input power receptacle (2) Grounding screw S5120V2-28P-PWR-LI Figure 74 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) Mode button (3) 10/100/1000BASE-T autosensing Ethernet port LED (4) SFP port LED (5) System status LED (SYS) (6) Mode LED (MODE) (7) Console port (CONSOLE) (8) SFP port Figure 75 Rear panel...
  • Page 61: S5120V2-28P-Hpwr-Li

    S5120V2-28P-HPWR-LI Figure 76 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) Console port (CONSOLE) (3) Mode button (4) 10/100/1000BASE-T autosensing Ethernet port LED (5) System status LED (SYS) (6) RPS status LED (RPS) (7) Mode LED (MODE) (8) SFP port LED (9) SFP port Figure 77 Rear panel (1) Grounding screw...
  • Page 62: S5120V2-12Tp-Hpwr-Li

    Figure 79 Rear panel (1) Grounding screw (2) AC-input power receptacle (3) DC-input power receptacle S5120V2-12TP-HPWR-LI Figure 80 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP port LED (4) System status LED (SYS) (5) Mode LED (MODE) (6) Mode button (7) Console port (CONSOLE)
  • Page 63: S5110V2-28P-Si

    S5110V2-28P-SI Figure 82 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP port LED (4) System status LED (SYS) (5) Console port (CONSOLE) (6) SFP port Figure 83 Rear panel (1) Grounding screw (2) AC-input power receptacle S5110V2-52P-SI Figure 84 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port...
  • Page 64: S5016Pv3-Ei

    Figure 85 Rear panel (1) Grounding screw (2) AC-input power receptacle S5016PV3-EI Figure 86 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP port LED (4) System status LED (SYS) (5) Console port (CONSOLE) (6) SFP port Figure 87 Rear panel (1) AC-input power receptacle...
  • Page 65: S5024Pv3-Ei

    S5024PV3-EI Figure 88 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP port LED (4) System status LED (SYS) (5) Console port (CONSOLE) (6) SFP port Figure 89 Rear panel (1) Grounding screw (2) AC-input power receptacle S5048PV3-EI Figure 90 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port...
  • Page 66: S5024Pv3-Ei-Pwr

    Figure 91 Rear panel (1) Grounding screw (2) AC-input power receptacle S5024PV3-EI-PWR Figure 92 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) Mode button (3) 10/100/1000BASE-T autosensing Ethernet port LED (4) SFP port LED (5) System status LED (SYS) (6) Mode LED (MODE) (7) Console port (CONSOLE) (8) SFP port Figure 93 Rear panel...
  • Page 67: S5024Pv3-Ei-Hpwr

    S5024PV3-EI-HPWR Figure 94 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) Mode button (3) 10/100/1000BASE-T autosensing Ethernet port LED (4) SFP port LED (5) System status LED (SYS) (6) Mode LED (MODE) (7) Console port (CONSOLE) (8) SFP port Figure 95 Rear panel (1) Grounding screw (2) AC-input power receptacle (3) DC-input power receptacle...
  • Page 68: S5024Fv3-Ei

    Figure 97 Rear panel (1) Grounding screw (2) AC-input power receptacle (3) DC-input power receptacle S5024FV3-EI Figure 98 Front panel (1) SFP port (2) 10/100/1000BASE-T autosensing Ethernet port (3) SFP port LED (4) System status LED (SYS) (5) 10/100/1000BASE-T autosensing Ethernet port LED (6) Console port (CONSOLE) Figure 99 Rear panel (1) AC-input power receptacle...
  • Page 69: S5500V3-24P-Si

    S5500V3-24P-SI Figure 100 Front panel (1) 10/100/1000BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port LED (3) SFP+ port LED (4) System status LED (SYS) (5) SFP port LED (6) Micro USB console port (7) Console port (CONSOLE) (8) SFP+ port (9) SFP port Figure 101 Rear panel (1) Grounding screw...
  • Page 70: S3100V3-10Tp-Si

    Figure 103 Rear panel (1) Grounding screw (2) AC-input power receptacle S3100V3-10TP-SI Figure 104 Front panel (1) 10/100BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port (3) 10/100BASE-T autosensing Ethernet port LED (4) SFP port LED (5) System status LED (SYS) (6) 10/100/1000BASE-T autosensing Ethernet port LED (7) Console port (CONSOLE) (8) SFP port...
  • Page 71: S3100V3-18Tp-Si

    S3100V3-18TP-SI Figure 106 Front panel (1) 10/100BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port (3) 10/100BASE-T autosensing Ethernet port LED (4) 10/100/1000BASE-T autosensing Ethernet port LED (5) SFP port LED (6) System status LED (SYS) (7) Console port (CONSOLE) (8) SFP port Figure 107 Rear panel (1) Grounding screw...
  • Page 72: S3100V3-52Tp-Si

    Figure 109 Rear panel (1) Grounding screw (2) AC-input power receptacle S3100V3-52TP-SI Figure 110 Front panel (1) 10/100BASE-T autosensing Ethernet port (2) 10/100BASE-T autosensing Ethernet port LED (3) 10/100/1000BASE-T autosensing Ethernet port (4) 10/100/1000BASE-T autosensing Ethernet port LED (5) Console port (CONSOLE) (6) System status LED (SYS) (7) SFP port (8) SFP port LED...
  • Page 73: S3100V3-10Tp-Pwr-Si

    S3100V3-10TP-PWR-SI Figure 112 Front panel (1) 10/100BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port (3) 10/100BASE-T autosensing Ethernet port LED (4) SFP port LED (5) System status LED (SYS) (6) Mode LED (MODE) (7) 10/100/1000BASE-T autosensing Ethernet port LED (8) Mode button (9) Console port (CONSOLE) (10) SFP port...
  • Page 74: S3100V3-28Tp-Pwr-Si

    Figure 115 Rear panel (1) AC-input power receptacle (2) Grounding screw S3100V3-28TP-PWR-SI Figure 116 Front panel (1) 10/100BASE-T autosensing Ethernet port (2) 10/100/1000BASE-T autosensing Ethernet port (3) 10/100BASE-T autosensing Ethernet port LED (4) System status LED (SYS) (5) RPS status LED (RPS) (6) Mode LED (MODE) (7) SFP port LED (8) 10/100/1000BASE-T autosensing Ethernet port LED...
  • Page 75: Technical Specifications

    Technical specifications S5560S-SI switch series Table 11 Technical specifications for the S5560S-SI switch series (1) Item S5560S-28P-SI S5560S-52P-SI S5560S-28S-SI S5560S-52S-SI 43.6 × 440 × 160 43.6 × 440 × 230 43.6 × 440 × 160 43.6 × 440 × 230 Dimensions (H ×...
  • Page 76 Table 12 Technical specifications for the S5560S-SI switch series (2) Item S5560S-28F-SI S5560S-28DP-SI Dimensions (H × W × 43.6 × 440 × 360 mm (1.72 × 43.6 × 440 × 360 mm (1.72 × 17.32 × 14.17 17.32 × 14.17 in) ≤...
  • Page 77: S5130S-Si & S5130S-Li Switch Series

    Item S5560S-28F-SI S5560S-28DP-SI Fire resistance UL60950-1/EN60950-1/IEC60950-1/GB4943 compliance S5130S-SI & S5130S-LI switch series Table 13 Technical specifications for the S5130S-SI & S5130S-LI non-PoE switch models S5130S-28S-SI S5130S-52S-SI Item S5130S-28F-SI S5130S-28S-LI S5130S-52S-LI Dimensions 43.6 × 440 × 160 mm (1.72 43.6 × 440 × 230 mm (1.72 43.6 ×...
  • Page 78 Rated voltage range: 100 VAC to 240 VAC @ 50 Hz or 60 Hz • Max voltage range: 90 VAC to 264 VAC @ 47 Hz to 63 Hz Input voltage H3C RPS1600-A DC input (only for the S5130S-52S-PWR-LI and S5130S-28S-HPWR-LI): • Rated voltage range: –54 VDC to –57 VDC •...
  • Page 79: S5120V2-Si & S5120V2-Li Switch Series

    Item S5130S-28S-PWR-LI S5130S-52S-PWR-LI S5130S-28S-HPWR-LI DC and AC inputs: –54 VDC to –57 VDC  Maximum PoE power 30 W per port AC: 370 W AC: 370 W Total PoE 170 W power DC: 740 W DC: 740 W Minimum AC: 37 W AC: 24 W power 20 W...
  • Page 80 S5120V2-10P-SI S5120V2-28P-SI S5120V2-52P- SI Item S5120V2-20P-LI S5120V2-10P-LI S5120V2-28P-LI S5120V2-52P- LI port SFP port • Rated voltage: 100 VAC to 240 VAC @ 50 or 60 Hz Input voltage • Max voltage: 90 VAC to 264 VAC @ 47 to 63 Hz Minimum 18 W power...
  • Page 81 • Rated voltage: 100 VAC to 240 VAC @ 50 or 60 Hz • Max voltage: 90 VAC to 264 VAC @ 47 to 63 Hz H3C RPS1600-A DC input (only for the S5120V2-28P-HPWR-LI and S5120V2-52P-PWR-LI Input switches): voltage •...
  • Page 82: S5110V2-Si Switch Series

    S5120V2-10P- S5120V2-28P- S5120V2-52P- S5120V2-28P- S5120V2-12 Item PWR-LI PWR-LI PWR-LI HPWR-LI TP-HPWR-LI system without fan trays trays to intake trays to intake trays to intake without fan cool air from the cool air from the cool air from the trays chassis left side chassis left side chassis left side and port side...
  • Page 83: S5000V3-Ei Switch Series

    Item S5110V2-28P-SI S5110V2-52P-SI Fire resistance UL60950-1/EN60950-1/IEC60950-1/GB4943 compliance S5000V3-EI switch series Table 18 Technical specifications for the S5000V3-EI non-PoE switch models Item S5016PV3-EI S5024PV3-EI S5048PV3-EI S5024FV3-EI 43.6 × 330 × 230 43.6 × 440 × 160 43.6 × 440 × 230 43.6 ×...
  • Page 84 • Rated voltage: 100 VAC to 240 VAC @ 50 or 60 Hz • Max voltage: 90 VAC to 264 VAC @ 47 to 63 Hz H3C RPS1600-A DC input (only for the S5024PV3-EI-HPWR and S5048PV3-EI-PWR Input voltage switches): •...
  • Page 85: S5500V3-Si Switch Series

    Item S5024PV3-EI-PWR S5024PV3-EI-HPWR S5048PV3-EI-PWR chassis left side and port chassis left side and port chassis left side and exhaust side and exhaust hot air side and exhaust hot air hot air from the chassis right from the right side from the chassis right side side Operating –5°C to +45°C (23°F to 113°F)
  • Page 86: S3100V3-Si Switch Series

    Item S5500V3-24P-SI S5500V3-48P-SI Fire resistance UL60950-1/EN60950-1/IEC60950-1/GB4943 compliance S3100V3-SI switch series Table 21 Technical specifications for S3100V3-SI non-PoE switch models Item S3100V3-10TP-SI S3100V3-18TP-SI S3100V3-28TP-SI S3100V3-52TP-SI 43.6 × 266 × 161 mm 43.6 × 266 × 161 43.6 × 440 × 160 43.6 ×...
  • Page 87 Rated voltage: 100 VAC to 240 VAC @ 50 or 60 Hz • Max voltage: 90 VAC to 264 VAC @ 47 to 63 Hz H3C RPS1600-A DC input (only for an S3100V3-28TP-PWR-SI switch): Input voltage • Rated voltage: –54 VDC to –57 VDC •...
  • Page 88 Item S3100V3-10TP-PWR-SI S3100V3-20TP-PWR-SI S3100V3-28TP-PWR-SI Chassis leakage UL60950-1/EN60950-1/IEC60950-1/GB4943 current compliance Melting current of 6.3 A/250 V 6.3 A/250 V 15 A/250 V power module fuse Using fixed fan trays to Using fixed fan trays to intake intake cool air from the cool air from the chassis left Cooling Natural cooling without fan...
  • Page 89: Appendix B Frus

    Appendix B FRUs The S5560S-28F-SI, S5560S-28DP-SI, and S5130S-28F-SI switches each provide two power module slots. One power module can meet the power requirement of the switch. You can install two power modules on the switch for redundancy. Table 23 describes the power modules available for the S5560S-28F-SI and S5130S-28F-SI switches.
  • Page 90: Appendix C Ports And Leds

    Appendix C Ports and LEDs Ports Console port The S5560S-28S-SI switch, S5560S-52S-SI switch, S5560S-28F-SI switch, S5560S-28DP-SI, S5130S-SI switch series, S5500V3-SI switch series, and S5130S-LI switch series provide a serial console port and a micro USB console port on the front panel. The S5560S-28P-SI switch, S5560S-52P-SI switch, S5120V2-SI switch series, S5120V2-LI switch series, S5110V2-SI switch series, S5000V3-EI switch series, and S3100V3-SI switch series provide only a serial console port.
  • Page 91: 10/100Base-T Autosensing Ethernet Port

    IMPORTANT: USB devices from different vendors vary in compatibilities and drivers. H3C does not guarantee correct operation of USB devices from all vendors on the S5560S-28DP-SI switch. If a USB device fails to operate on the switch, replace it with one from another vendor.
  • Page 92 • SFP ports 1 to 26 on an S5024FV3-EI switch. IMPORTANT: To use transceiver modules with a maximum transmission distance greater than or equal to 80 km (49.71 miles) on the following switches, make sure the ambient temperature does not exceed 40°C (104°F).
  • Page 93 GE SFP Modal Central Cable Connector transceiver bandwidth transmission wavelength specifications module/cable (MHz*km) distance 50/125 µm 550 m (1804.46 multi-mode 500/400 optical fiber 62.5/125 µm 550 m (1804.46 multi-mode optical fiber 9/125 µm SFP-GE-LX-SM131 10 km (6.21 1310 nm single-mode miles) optical fiber 9/125 µm...
  • Page 94: Sfp+ Port

    As a best practice, use H3C transceiver modules and cables for the switch. • H3C transceiver modules and cables are subject to change over time. For the most up-to-date list of H3C transceiver modules and cables, contact your H3C sales representative or technical support engineer.
  • Page 95 • GE SFP transceiver modules in Table • 10-GE SFP+ transceiver modules in Table • 10-GE SFP+ cables in Table Table 30 10-GE SFP+ transceiver modules available for the SFP+ ports 10-GE SFP+ Modal Central transceiver Connector Fiber bandwidth transmission wavelength module (MHz*km)
  • Page 96: Combo Interface

    As a best practice, use H3C transceiver modules and cables for the switch. • H3C transceiver modules and cables are subject to change over time. For the most up-to-date list of H3C transceiver modules and cables, contact your H3C sales representative or technical support engineer.
  • Page 97: Management Ethernet Port Led

    Management Ethernet port LED The S5560S-28F-SI, S5560S-28DP-SI, and S5130S-28F-SI switches each provide a LED for the management Ethernet port to indicate its operating status. Table 33 Management Ethernet port LED description Management Ethernet port LED (ACT/LINK) status Description Steady green A link is present on the port.
  • Page 98: Sfp/Sfp+ Port Led

    Table 36 Description for the mode LED LED mark Status Description Steady green The port LEDs are showing link state of the ports. Flashing green (Available only for The port LEDs are showing the PoE status of the ports. Mode LED PoE switch models) (MODE) The port LEDs work in conjunction to indicate the IRF member ID...
  • Page 99 10/100BASE-T autosensing Ethernet port Mode LED status or 10/100/1000BASE-T Description autosensing Ethernet port LED status No link is present on the port. Steady green PoE power supply is normal. • The maximum PoE power provided by the port fails to meet the power requirement of the PD.

Table of Contents