Access Control Using the PassPoint Access Control System

The VISTA-128BPEN interfaces with the PassPoint ACS via the VISTA Gateway Module (VGM). The VGM is connected
between the ECP bus (keypad terminals) of the control and the network bus of the PassPoint ACS.
The control sends the VGM its status information, event log entries, and entry/exit requests (inputs programmed with
response type Access Point) from keypads, hardwired zones, and RF transmitters.
The VGM then reformats and retransmits this information to the Main Logic Board, (MLB) on the PassPoint ACS
network bus.
Interfacing the VISTA-128BPEN with the PassPoint Access Control System via the VISTA Gateway Module is not
U L
permissible for UL installations.
Wiring the VISTA Gateway Module
The VISTA Gateway Module is connected between the ECP bus (VISTA-128BPEN keypad terminals) and the network
bus of the PassPoint Access Control System. See Figure 3-30 for the proper wiring connections.

Installing a 4100SM

The 4100SM is used to print event log reports to a serial printer or to interface the control with a computer equipped
with Home Automation software.
When using the 4100SM, the system can interface with either a serial printer or Home Automation. It cannot do
both.
NOTE: See SECTION 4: Programming for the programming details when using the 4100SM.
Printer/Computer Configurations
Configure the serial printer or the Home Automation computer as follows:
8 data bits, no parity, 1 stop bit
1200 baud
Connecting the 4100SM to a Serial Printer
To connect a serial printer using the 4100SM, refer to Figure 3-31and perform the following steps:
Action
Step
Connect terminal 1 on the 4100SM to the Violet wire on the 4142TR cable.
1
Connect terminal 6 on the 4100SM to the Brown wire on the 4142TR cable.
2
Connect the 4142TR cable to J8 on the control.
3
Connect terminals 8 and 7 of the 4100SM to terminals 6 and 7 (aux. power (+) and (-)), respectively of the
4
control.
Connect the UL EDP Listed serial printer to the 4100SM Interface Module.
5
The 4100SM Module is supplied with a 10-foot RS232 cable. A longer cable can be used if the VISTA-
128BPEN is separated from the serial printer by more than 10 feet, but the total cable length should be less
than 50 feet.
PROM C
4-PIN
KEYPAD
PLUG
TRANSFORMER

Figure 3-30: Wiring the VISTA Gateway Module

}
ECHELON NETWORK
(PASSPOINT ACS)
GREEN
}
BLACK
TO
CONTROL'S
RED
KEYPAD
TERMINALS
YELLOW