Honeywell VISTA-128BPEN Installation And Setup Manual page 20

Commercial burglary partitioned security system with scheduling
Table of Contents

Advertisement

Vista-128BPEN Installation and Setup Guide
Multi-Panel View Mode
To perform a function in the Multi-Panel View mode, follow the steps below:
Step
Action
1
Enter User Code (for users 001-050) + [#] + [87].
The keypad displays the following typical display:
ALLPANEL 1 2 3 4 5 6 7 8
STATUS
where "12345678" are the panel ID numbers and "xxxxxxxx" is the overall status of each panel. Status
indications include:
A = Armed Away
I = Armed Instant
B = Bypassed/Ready
F = Fire Alarm
C = Comm Fail
NOTE: See table later in this section for priority of displays.
2
The following functions can be performed::
Press [1] to attempt to disarm all partitions on all panels.
Press [2] to attempt to arm AWAY all partitions on all panels.
Press [3] to attempt to arm STAY all partitions on all panels.
Press [4] to attempt to arm MAXIMUM all partitions.
Press [7] to attempt to arm INSTANT all partitions.
Press [0] to exit mode. After a few seconds, the keypad displays the status of the original partition of the
original panel for the keypad. Also, this mode will end in approximately 2 minutes if no keys are pressed.
NOTES:
When performing any of the arming commands, if there are faults in any of the partitions of a panel, the
system will not arm that panel, but will arm all the other partitions of the other panels.
When performing either a STAY or INSTANT arm command, the system always arms in mode 1 (see the
VISTA-128BPEN User Guide for a detailed explanation of the STAY and INSTANT arming modes).
The user cannot execute another panel linking mode. In order to perform another panel linking mode or to
access a different remote panel, the user must first exit this mode (return to the original control panel).
Priority of Displays for Multi-Partition and Multi-Panel Modes
This table shows the priority of displays if more than one of these conditions exists at the same time.
Priority
1
Fire Alarm
2
All Other Alarms
3
AC Loss
4
Comm Fail
5
System Low Battery
6
Trouble
7
Bypass
2-6
x x x x x x x x
S = Armed Stay
R = Ready
✴ = Alarm
P = AC Power Failure
Description
Display
F
P
C
L
T
B
M = Armed Maximum
N = Not Ready
T = Trouble
L = Low System Battery
Priority
Description
8
Not Ready
9
Ready
10
Armed STAY
11
Armed AWAY
12
Armed INSTANT
13
Armed MAXIMUM
Display
N
R
S
A
I
M

Hide quick links: