Figure 3-11: 4-Wire Smoke Detectors - Honeywell VISTA-128BPEN Installation And Setup Manual

Commercial burglary partitioned security system with scheduling
Table of Contents

Advertisement

Power to 4-wire smoke detectors must be supervised with an EOL device (use a System Sensor EOLR-1 EOL relay
U L
module connected as shown in Figure 3-11 ).
To wire 4-wire smoke detectors to zones 1-8, perform the following steps:
Step
Action
1
Select 4-wire smoke detectors (see list of compatible detectors shown previously).
2
Connect detectors (including heat detectors, if used) across terminals of the zone selected. All detectors must
be wired in parallel. See Figure 3-11.
NOTE: If you are using the J7 output trigger to reset the smoke detectors, refer to Smoke Detector Reset later
in this section for the wiring instructions.
3
Connect the EOLR at the last detector in the loop across the zone's terminals. You must connect the EOLR
across the loop wires at the last detector.
AUXILIARY
POWER
TERMINALS
NOTES:
· PROGRAM THE RELAY TO
TRANSFER ON FIRE ZONE
RESET (ACTIVATION CODE 54).
SEE 4204 RELAY MODULE
SECTION FOR DETAILS.
· SECOND CODE AND OFF
ENTERED AT CONSOLE
MOMENTARILY INTERRUPTS
DETECTOR POWER.
Using 2-Wire Latching Glassbreaks on Zone 8
Zone 8 can support 2-wire glassbreak detectors. The zone provides enough standby current to power up to 50 2-wire
glassbreak detectors meeting the requirements listed below.
Compatible Glassbreak Detectors
Use detectors that meet the following ratings:
Standby
5VDC–13.8VDC
Voltage:
Standby
Greater than 20k ohms (equivalent
Resistance:
resistance of all detectors in parallel)
Alarm
Less than 1.1k ohms (see note below)
Resistance:
Alarm
2mA–10mA
Current:
Reset Time:
Less than 6 seconds
NOTES:
You can use detectors that exceed 1.1k ohms in alarm, provided they maintain a voltage drop of less than 3.8 volts in
alarm.
The ADEMCO ASC-SS1 detector has been tested and found to be compatible with these ratings.
_
TO
+
NO CONNECTION
C
NC
NO
RESET
RELAY 1, 2, 3, OR 4
4204 RELAY MODULE

Figure 3-11: 4-Wire Smoke Detectors

GLASSBREAK
DETECTOR
2000
OHMS
EOLR
Figure 3-12: Wiring Latching Glassbreaks to Zone 8
4-WIRE
SMOKE
DETECTORS
+
+
_
HEAT
DETECTOR
_
+
TO
FIRE ZONE
TERMINALS
ZONE 8
21
LATCHING TYPE GLASS
BREAK DETECTOR LOOP
22
Installing the Control
_
+
EOL POWER
SUPERVISION
RELAY MODULE
_
A77-716B
SHOWN POWERED.
RELAY OPENS WHEN
POWER IS LOST.
2k
EOLR
(+)
(-)
V128BP-002-V0
3-9