Scheduled Download; Direct-Wire Downloading; Telco Handoff; Figure 7-1: Direct-Wire Downloading Connections - Honeywell VISTA-128BPEN Installation And Setup Manual

Commercial burglary partitioned security system with scheduling
Table of Contents

Advertisement

Vista-128BPEN Installation and Setup Guide

Scheduled Download

The VISTA-128BPEN can be programmed to
periodically and automatically call the downloader.
When this option is set up, the system will call the
downloader at a scheduled time. Once the connection is
established with the modem, the downloader controls
which functions are performed (download, arm, upload
event log, etc.).
The programmable options for the scheduled download
are located in the #93 Menu Mode section under the
main menu prompt Scheduled Check-in.

Direct-Wire Downloading

The VISTA-128BPEN can be downloaded without using
a modem or telephone line by using a 4100SM Serial
Module and Compass Downloading Software. The
direct-wire downloading connection is to be temporary,
and is not part of the permanent installation. Direct-
wire downloading is meant as a tool for the installer
during the installation process.
The connections between the control and the
4100SM are different than those shown in the
4100SM Installation Instructions. See Figure 7-
1 for the correct connections. In addition, in
place of the green wire, referred to in step 2 of
the "IN CASE OF DIFFICULTY" section of the
4100SM Instructions, use the violet wire instead.

Telco Handoff

Telco handoff is another method of getting on-line with the downloader. The installer or customer enters the User Code
+ [#] + [1], while on the phone line with the computer's modem phone line. The customer will get cut-off and the panel
and download computer will establish a connection.
7-4
1
2
3
4
5
6
7
NU

Figure 7-1: Direct-Wire Downloading Connections

The options are as follows:
Check-in interval (weekly, monthly quarterly,
yearly)
Quarter of the year (if quarterly is selected)
Month of the year (if monthly, quarterly, or yearly
is selected)
Day of the month (if monthly, quarterly, or yearly
is selected)
Day of the week (if weekly is selected)
Time of day
Refer to the #93 Menu Mode section in the
Programming Guide for sequence of the prompts.
Connector J8 on the main PC board (see the Summary
of Connections diagram on the inside back cover of this
manual) is intended to be interfaced to either a local
serial printer (see SECTION 3: Installing the Control)
or a computer. Make connections to a computer as
shown below. Note that the violet wire connection
for a computer differs from that used when
connecting a serial printer.
8
9
J8 CONNECTOR
4142TR CABLE (SUPPLIED WITH 4100SM)
4100SM SERIAL MODULE
To TB6 Aux. Power (+)
8
+ PWR
(25mA current draw)
7
- (GND)
To TB7 Aux. Power (-)
6
RXD
5
not used
4
not used
3
TXD
2
not used
DTR
1
RED
BLUE WHITE
4100SM-019-V1

Hide quick links: