Honeywell VISTA-128BPEN Installation And Setup Manual page 90

Commercial burglary partitioned security system with scheduling
Table of Contents

Advertisement

Vista-128BPEN Installation and Setup Guide
1.
Enter the schedule number (01-20) and time
window number (01-20), and note the day of the
week the action is desired.
2.
Enter the code for the desired action and
action specifier. The action codes represent the
events that are to take place when the scheduled
time is reached. Each action also requires an
action specifier, which defines what the action will
affect (relay, relay group, partition, zone list, user
group). The action specifier varies, depending on
the type of action selected.
The following is a list of the Action Codes (desired
actions) used when programming Time-Driven
events. Note that these codes are independent of
the relay codes programmed during Output
Programming in the #93 Menu Mode.
Relay Commands
Action Code
Action
01
Relay On
02
Relay Off
03
Relay Close for 2 seconds
Relay Close XX minutes (set
04
in field 1*74)
Relay Close YY seconds (set
05
in field 1*75)
06
Relay Group On
07
Relay Group Off
Relay Group Close for 2
08
seconds
Relay Group Close XX
09
minutes (set in field 1*74)
Relay Group Close YY
10
seconds (set in field 1*75)
Arm/Disarm Commands
Action Code
Action
20
Arm-STAY
21
Arm AWAY
22
Disarm
Force Arm STAY (Auto-
23
bypass faulted zns)
Force Arm AWAY (Auto-
24
bypass faulted zns)
25
Arm INSTANT
26
Arm MAXIMUM
The auto-arm warning (field 2*06) applies
when using Time-Driven events to auto-arm.
Temporary schedules do not override an
auto-arming or auto-disarming programmed
in Time-Driven events.
The auto-arming window cannot be extended
using the Installer Code + #82 Mode.
6-8
Bypass Commands
Action Code
30
31
Open/Close Windows
Action Code
40
41
42
Access Control Commands
Action Code
55
56
Action Specifier
Relay #
57
Relay #
58
Relay #
59
60
Relay #
61
Relay #
62
Relay Group #
63
Relay Group #
64
65
Relay Group #
66
Relay Group #
67
68
Relay Group #
69
Action Specifier
70
Partition(s)
71
Partition(s)
Partition(s)
72
73
Partition(s)
74
Partition(s)
77
78
Partition(s)
Partition(s)
Action
Auto bypass – Zone list
Auto unbypass – Zone list
Action
Enable Opening Window by
partition
Enable Closing Window by
partition
Enable Access Window for
access group
Action
Access Point Grant
Access Point Grant with
Override
Access Point Protect
Access Point Bypass
Access Point Lock
Access Point Exit
Access Point Group Grant
Access Point Group Grant
with Override
Access Point Group Protect
Access Point Group Bypass
Access Point Group Lock
Access Point Group Exit
Access Point Partition Grant
Access Point Partition Grant
with Override
Access Point Protect by
Partition
Access Point Bypass by
Partition
Access Point Lock by
Partition
Access Point Exit by Partition
Access Point Trigger On
Access Point Trigger Off
Access Point Group Enable
Access Point Group Disable
Action Specifier
Zone list #
Zone list #
Action Specifier
Partition(s)
Partition(s)
Access Group
Action Specifier
Access Point #
Access Point #
Access Point #
Access Point #
Access Point #
Access Point #
Group #
Group #
Group #
Group #
Group #
Group #
Partition #
Partition #
Partition #
Partition #
Partition #
Partition #
Trigger #
Trigger #
Group #
Group #

Hide quick links: