Zone Response Type Definitions - Honeywell VISTA-128BPEN Installation And Setup Manual

Commercial burglary partitioned security system with scheduling
Table of Contents

Advertisement

ZONE #
1st
2nd
1
01
00
2
02
00
3
03
00
4
04
00
5
05
00
6
06
00
7
07
00
8
08
00
9
09
00
10
10
00
11
11
00
12
12
00
13
13
00
14
14
00
15
15
00
16
01
00
17
02
00
18
03
00
19
04
00
20
05
00
21
06
00
22
07
00
23
08
00
24
09
00
25
10
00
26
11
00
27
12
00
28
13
00
29
14
00
30
15
00
31
01
00
32
02
00
33
03
00
34
04
00
35
05
00
36
06
00
37
07
00
38
08
00
39
09
00
40
10
00
41
11
00
42
12
00
43
13
00
44
14
00
45
15
00
46
01
00
47
02
00
48
03
00
49
04
00

Zone Response Type Definitions

Each zone must be assigned a zone type, which defines
the way in which the system responds to faults in that
zone. There are three keypad-activated zones (panic
keys; see note) for each partition, a polling loop
supervision zone, and four RF supervisory zones, two
for each RF receiver installed. Zone types are defined
below.
Type 00: Zone Not Used
Program with this zone type if the zone is not used.
Type 01: Entry/Exit #1 Burglary
Provides entry delay whenever the zone is faulted and
the system is armed in the AWAY or STAY mode. When
Communication Defaults for Zones
ZONE #
1st
2nd
50
05
00
51
06
00
52
07
00
53
08
00
54
09
00
55
10
00
56
11
00
57
12
00
58
13
00
59
14
00
60
15
00
61
01
00
62
02
00
63
03
00
64
04
00
65
05
00
66
06
00
67
07
00
68
08
00
69
09
00
70
10
00
71
11
00
72
12
00
73
13
00
74
14
00
75
15
00
76
01
00
77
02
00
78
03
00
79
04
00
80
05
00
81
06
00
82
07
00
83
08
00
84
09
00
85
10
00
86
11
00
87
12
00
88
13
00
89
14
00
90
15
00
91
01
00
92
02
00
93
03
00
94
04
00
95
05
00
96
06
00
97
07
00
98
08
00
ZONE #
1st
99
09
100
10
101
11
102
12
103
13
104
14
105
15
106
01
107
02
108
03
109
04
110
05
111
06
112
07
113
08
114
09
115
10
116
11
117
12
118
13
119
14
120
15
121
01
122
02
123
03
124
04
125
05
126
06
127
07
128
08
601-632
00
800-830
00
970
00
988
00
990
00
992 (DURESS)
11
995
00
996
00
997
06
999
06
ALARM RST.
00
TROUBLE
00
TRBLE. RST
00
BYPASS
00
BYP. RST.
00
the panel is armed in the INSTANT or MAXIMUM
mode, no entry delay is provided. Exit delay begins
whenever the control is armed, regardless of the arming
mode selected. These delays are programmable.
Assign this zone type to zones that are used for primary
entry to and exit from the facility.
Type 02: Entry/Exit #2 Burglary
Provides a secondary entry delay, if the system is
armed in the AWAY or STAY modes and the zone is
faulted. When the panel is armed in the INSTANT or
MAXIMUM mode, no entry delay is provided.
Secondary exit delay begins whenever the control is
Section 4 – Programming
2nd
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
4-5