Access Control Using Ademco Passpoint Acs); Figure 3-35: Wiring Vistakey; Figure 3-36. Wiring The Vista Gateway Module - Honeywell ADEMCO VISTA-120 Installation And Setup Manual

Partitioned security system with scheduling
Hide thumbs Also See for ADEMCO VISTA-120:
Table of Contents

Advertisement

VISTA-120 Installation and Setup Guide
FOR ADDITIONAL RATINGS AND
SPECIFICATIONS, REFER TO
INSTALLATION INSTRUCTION
FOR THE VISTAKEY-SK.
WEEKLY TESTING IS REQUIRED
TO ENSURE PROPER OPERATION
OF THIS SYSTEM.

Access Control Using ADEMCO PassPoint ACS)

The VISTA-120 interfaces with the PassPoint ACS via
the VISTA Gateway Module (PTVGM). The PTVGM is
connected between the ECP bus (keypad terminals) of
the control and the network bus of the PassPoint ACS.
The control sends the PTVGM its status information,
event log entries, and entry/exit requests (inputs
programmed with response type Access Point) from
keypads, hardwired zones, and RF transmitters. The
PTVGM then reformats and retransmits this
information to the Main Logic Board, (MLB) on the
PassPoint ACS network bus.
Wiring the VISTA Gateway Module
The VISTA Gateway Module is connected between the
ECP bus, (VISTA-120 keypad terminals) and the
network bus of the PassPoint Access Control System.
See Figure 3-36 for the proper wiring connections:
3-24
1
2 3 4 5 6 7 8 9 10
11 12
TB 1
K1
DOOR
CONTROL
RELAY
1
2
3
4
TB 3
5
6
7
8
+
VISTAKEY

Figure 3-35: Wiring VistaKey

14V MAX (12V @ 85-160mA Nominal)
GND
POLLING LOOP +
POLLING LOOP -
GND
ZONE A (DSM)
ZONE B (RTE)
ZONE C (General)
GND
POLE Door Strike/Mag Coil
N/C MAG COIL POWER
N/O DOOR STRIKE POWER
RELAY CONTACT RATINGS:
3A @ 28VDC MAX. (RESISTIVE LOAD)
READER INTERFACE CABLE
RDR LED
(ORANGE)
GND
(BLACK)
DATA 1
(WHITE)
DATA 0
(GREEN)
GND
+5V
+12V
(RED)
TRIGGER (SEE NOTE 3)
NOTE 1: VISTAKEY TB3 TERMINAL 5 IS A GROUND AND MAY BE
USED INSTEAD OF TB3 TERMINAL 2. TB3 TERMINALS 2 AND 5 ARE
A COMMON GROUND.
NOTE 2: WHEN USING TRIGGER TO TURN ON AN LED OR BUZZER,
RETURN HIGH SIDE OF LED OR BUZZER TO TB3 TERMINAL 7.
TRIGGER RATING IS 15mA AT 12VDC.
PROM C
TRANSFORMER

Figure 3-36. Wiring the VISTA Gateway Module

TO ALARM SYSTEM
CONTROL PANEL
POLLING LOOP TERMINALS.
+ 12 VDC TO ONLY
ONE OF THESE INPUTS.
(FROM TB1-1)
NO
CONNECTION
V120-003-V0
}
ECHELON NETWORK
(PASSPOINT ACS)
4-PIN
KEYPAD
PLUG
GREEN
}
TO
BLACK
CONTROL'S
RED
KEYPAD
TERMINALS
YELLOW