When the panel has a message to transmit to the central station, it seizes the line, goes off hook, and then triggers the
Module to connect the RING side of the telephone line to earth ground. The panel causes the module to break the
connection between RING and earth ground when it obtains a dial tone.
You cannot use Output 1 for the Ground Start if you are using it for a Smoke Detector Reset or an AAV module.
To install the 675 Ground Start Module, perform the following steps:
Step
Action
1
Determine which side of the telephone line is the RING side by connecting the (+) lead of a DC voltmeter to
earth ground, and the (-) lead to one side of the telephone line.
The wire that reads + 50VDC is the RING side.
2
Connect the Ground Start Module to the panel's J7 connector trigger output 1, to auxiliary power, and to the
RING side of the telephone line as shown in Figure 3-23.
3
Program field 1✳46 Auxiliary Output Enable with a [0].

Installing a Remote Keyswitch

A UL-Listed remote keyswitch, such as the Honeywell 4146, can be used for remote arming/disarming of the burglary
portion of the system and for silencing alarms. The keyswitch can operate in only one particular partition.
The keyswitch is wired across zone 7. This zone is no longer available as a protection zone. Be sure to program Zone 7
with a response type (e.g., type 10).
Operation
A momentary short across zone 7 arms the partition in the AWAY mode, and a short held for more than 10 seconds
arms the partition in STAY mode 1. A subsequent short disarms the partition.
The keyswitch LEDs indicate the partition's status (see table below).
A momentary short across Zone 7 silences alarm bell and keypad sounds, and disarms the system if it was armed. A
subsequent short across Zone 7 clears the alarm memory indication and resets 2-wire smoke and glassbreak
detectors (if used).
LED Indications
Green
Red
On
Off
Off
Off
Off
On Steady
Off
Slow Flash
Off
Rapid Flash
The keyswitch reports as user 0, if Open/Close reporting is enabled in field ✳40.
3-20
GROUND START
675
TRIGGER
GROUND
BLUE
START
MODULE
TO AUX. POWER
BLACK
TERM. 7
(CUT ORANGE
JUMPER)
TO AUX. POWER
VIOLET
TERM. 6
(50mA CURRENT DRAW)
IF USED:
1. OUT 1 IS NO LONGER
USABLE FOR SMOKE DETECTOR RESET
TO
TO
(SEE FIELD 1*46).
TELCO
EARTH
2. OUT 2, 3, 4 CAN STILL BE
RING
GROUND
USED TO PROVIDE ALARM
STATUS INDICATIONS OR
TO OPERATE A KEYSWITCH
(SEE FIELD *15).
3. THE 675 IS NOT UL LISTED.

Figure 3-23: Ground Start Module Connections

Indication
Disarmed & Ready
Disarmed & Not Ready
Armed Away
Armed Stay
Alarm Memory
J7 CONNECTOR
4142TR
CABLE
GRAY (GROUND)
YELLOW (OUT 1)
WHITE (GROUND)
RED (OUT 2)
GREEN (GROUND)
BROWN (OUT 3)
BLUE (GROUND)
BLACK (OUT 4)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents