VISTA-128BP/VISTA-250BP Installation and Setup Guide
Step
Action
4
Connect the leads to TB1 in the following
order:
a. All ground leads to terminals 2, 5, and 9.
b. The DSM, (optional) RTE, and General
Purpose leads to terminals 6, 7, and 8,
respectively.
c. Door strike (or mag lock) lead to terminal
10.
d. Local +12V or +24V supply lead to
terminal 1.
e. Local +12V or +24V supply lead to the N/C
relay terminal 11 (if a mag lock is being
used), OR to the N/O relay terminal 10 (if
a door strike is being used).
5
Connect the (–) polling loop and (+) polling
loop leads (from the VISTA-128BP/VISTA-
250BP) to terminals 4 and 3, respectively.
6
Set the Address Select switch to the desired
access door number (1-15).
7
Repeat steps 1 through 6 for each VistaKey
being installed.
THIS DEVICE COMPLIES WITH PART 15 CLASS A
LIMITS OF FCC RULES. OPERATION IS SUBJECT
TO THE FOLLOWING TWO CONDITIONS:
(1) IT MAY NOT CAUSE HARMFUL INTERFERENCE.
(2) IT MUST ACCEPT ANY INTERFERENCE THAT
MAY CAUSE UNDESIRED OPERATION.
THIS EQUIPMENT SHOULD BE INSTALLED IN
ACCORDANCE WITH THE NATIONAL FIRE
PROTECTION ASSOCIATION'S STANDARDS 70 &
74 (NATIONAL FIRE PROTECTION ASSOC.,
BATTERYMARCH PARK, QUINCY, MA. 02269).
PRINTED INFORMATION DESCRIBING PROPER
MAINTENANCE, EVACUATION PLANNING AND
REPAIR SERVICE IS TO BE PROVIDED WITH
THIS EQUIPMENT.
FOR ADDITIONAL RATINGS AND
SPECIFICATIONS, REFER TO
INSTALLATION INSTRUCTION
FOR THE VISTAKEY-SK.
WEEKLY TESTING IS REQUIRED
TO ENSURE PROPER OPERATION
OF THIS SYSTEM.

Access Control Using the PassPoint Access Control System

The VISTA-128BP/VISTA-250BP interfaces with the
PassPoint ACS via the VISTA Gateway Module
(VGM). The VGM is connected between the ECP bus
(keypad terminals) of the control and the network bus
of the PassPoint ACS.
3-26
WWW.DIYALARMFORUM.COM
1
2 3 4 5 6 7 8 9 10
VISTAKEY

Figure 3-31: Wiring the VistaKey

WWW.DIYALARMFORUM.COM
Connecting the Card Reader
Lead from Reader
Green LED
Ground*
DATA 1 (Clock)
DATA 0 (Data)
+5VDC†
+12VDC†
*
TB-3 Terminal 5 is also a ground and may be used
instead of terminal 2. Terminals 2 and 5 are a common
ground.
† Connect to +5VDC OR +12VDC per reader
manufacturer's specification.
14V MAX (12V @ 85-160mA Nominal)
GND
POLLING LOOP +
POLLING LOOP -
GND
ZONE A (DSM)
ZONE B (RTE)
ZONE C (General)
GND
POLE Door Strike/Mag Coil
N/C MAG COIL POWER
N/O DOOR STRIKE POWER
RELAY CONTACT RATINGS:
11 12
3A @ 28VDC MAX. (RESISTIVE LOAD)
TB 1
K1
DOOR
READER INTERFACE CABLE
CONTROL
RELAY
RDR LED
(ORANGE)
1
GND
(BLACK)
2
DATA 1
(WHITE)
3
DATA 0
(GREEN)
4
TB 3
GND
5
+5V
6
+12V
(RED)
7
8
TRIGGER (SEE NOTE 3)
+
NOTE 1: USE UL LISTED ENERGY CABLE FOR ALL CONNECTIONS.
NOTE 2: VISTAKEY TB3 TERMINAL 5 IS A GROUND AND MAY BE
USED INSTEAD OF TB3 TERMINAL 2. TB3 TERMINALS 2 AND 5 ARE
A COMMON GROUND.
NOTE 3: WHEN USING TRIGGER TO TURN ON AN LED OR BUZZER,
RETURN HIGH SIDE OF LED OR BUZZER TO TB3 TERMINAL 7.
TRIGGER RATING IS 15mA AT 12VDC.
The control sends the VGM its status information,
event log entries, and entry/exit requests (inputs
programmed with response type Access Point) from
keypads, hardwired zones, and RF transmitters.
Lead Color
To VistaKey TB3
Terminal #
Orange
1
Black
2
White
3
Green
4
Red†
6
Red†
7
TO ALARM SYSTEM
CONTROL PANEL
POLLING LOOP TERMINALS.
+ 12 VDC TO ONLY
ONE OF THESE INPUTS.
(FROM TB1-1)
NO
CONNECTION