Figure 3-34: Uvs Connections To The Control Panel - Honeywell VISTA-128BPEN Installation And Setup Manual

Commercial burglary partitioned security system with scheduling
Table of Contents

Advertisement

If the phone plug is disconnected from the control, the premise's phones will not operate.
NOTES:
When the AAV indicates that the audio alarm verification session is completed, all keypad sounds are restored.
Sirens are restored if the alarm timeout period has not expired.
As part of its fail-safe software, the control limits all audio alarm verification sessions to 15 minutes. This is
because once the session begins, the AAV Module controls the duration.
If a new Fire alarm should occur during a session, the control breaks the phone connection and sends the new Fire
Alarm report, then re-triggers the AAV Mode. All other dialer messages triggered during ongoing conversation are
held until either the AAV Module signals that it is inactive, or the 15-minute timeout occurs.
SW
1
UVST 1 AUX AUDIO, ON = ENABLED
2
UVST 2 AUX AUDIO, ON = ENABLED
3
UVST 3 AUX AUDIO, ON = ENABLED
4
UVST 4 AUX AUDIO, ON = ENABLED
5
UVST 5 AUX AUDIO, ON = ENABLED
6
UVST 6, ON = OUTSIDE, OFF = INSIDE
7
UVST 7, ON = OUTSIDE, OFF = INSIDE
8
VOICE TRIGGER, ON = IMMED, OFF = CALLBACK
SHIPPED WITH ALL SWITCHES IN "ON" POSITION.
ALTERNATE
+12 VDC IN FOR
PLUG-IN WALL PACK
(SEE NOTE 2)
UVCM AND UVST SUMMARY OF CONNECTIONS
Refer to UVS Installation and Setup Guide K4214 for complete information
SW
SWITCH BANK 1
1
FUTURE USE, SET TO ON
2
FUTURE USE, SET TO ON
3
TELEPHONE RING, ON = ENABLED
4
END USER VOICE, ON = DISABLED
5
FUTURE USE, SET TO ON
6
CS CODE LEARN, ON = DISABLED
7
USER CODE LEARN, ON = DISABLED
8
FUTURE USE, SET TO ON
ON
ON
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
SWITCH BANK 1
SWITCH BANK 2
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34
MUSIC SOURCE
OPTIONAL
(NOTE 4)
CONTROL PANEL
VOLUME CONTROL DIAL
UVST
TYPICAL 1 OF 7
COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION NO. AC3 USA-40133-SP-T
RINGER EQUIVALENCE: 1.0B
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION.

Figure 3-34: UVS Connections to the Control Panel

SWITCH BANK 2
NOTE 1: CONNECT TO PROPER EARTH GROUND.
NOTE 2: POWER MAY ALSO BE SUPPLIED BY A LISTED CLASS 2
POWER SUPPLY RATED 12VDC, MIN 600mA CONNECTED TO THE
UVCM +12VDC IN AND GND TERMINALS.
NOTE 3: SOME CONTROL PANELS USE BUILT-IN TRIGGER AND SOME
USE 4204 RELAY MODULE. REFER TO AAV SECTION OF CONTROL PANEL
INSTALLATION AND SETUP GUIDE FOR CONNECTION.
NOTE 4: EITHER MUSIC SOURCE OR 4286 VIP MODULE CAN BE USED BUT
NOT AT THE SAME TIME.
NOTE 5: DO NOT CONNECT IF 4286 VIP MODULE IS USED.
AUDIO OUT
GND
INCOMING RING
INCOMING TIP
HANDSET RING
HANDSET TIP
SPEAKER
SPEAKER
VOLUME
VOLUME
CONTROL
TRIM POT
4286 VIP
MODULE
OPTIONAL
(NOTE 4)
P3
KEYED
HEADER
P2
P1
FOR COMPLETE INFORMATION, SEE
4286 VIP MODULE INSTRUCTIONS.
Installing the Control
AUXILIARY
AUDIO LEVEL
ADJUSTMENT
TRIM POT
NOTE 1
RJ31X
TIP
INCOMING
PLUG
JACK
TELCO
RING
LINES
DIRECT
CONNECT
CORD
P7
ANSWERING
MACHINE
PREMISES
ANSWERING
MACHINE AND
PHONE (S)
WARNING: TO PREVENT RISK
OF ELECTRICAL SHOCK,
DISCONNECT TELCO JACK
BEFORE SERVICING THIS PANEL.
3-31