Honeywell VISTA-128BPEN Installation And Setup Manual page 78

Commercial burglary partitioned security system with scheduling
Table of Contents

Advertisement

Vista-128BPEN Installation and Setup Guide
FIELD
TITLE and DATA ENTRIES
Access Control Dialer Enables
1*35
0 = disable
1 = enable
Call Waiting Defeat
1*42
0 = disable
1 = enable
Permanent Keypad Display
1*43
Backlighting (partition-specific)
0 = disable
1 = enable
Wireless Keypad Tamper Detect
1*44
0 = disable
1 = enable
Auxiliary Output Mode
1*46
0 = ground start output.
1 = smoke detector reset.
2 = keypad sounds at an auxiliary sounder.
3 = AAV module.
Chime on External Siren
1*47
(partition-specific)
0 = disable
1 = enable
Wireless Keypad Assignment
1*48
0 = none
1-8 = partition number
Suppress Transmitter
1*49
Supervision Sound
0 = disable
1 = enable
Disable Download Callback
1*53
0 = callback required
1 = no callback required
European Date Format
1*55
0 = disable (mm/dd/yy)
1 = enable (dd/mm/yy)
AC 60Hz or 50Hz
1*56
0 = 60Hz
1 = 50Hz
5-10
EXPLANATION
There are six entries for this field as follows: Trace, Trouble, Not Used,
Bypass, System and Alarm.
If Trace is enabled, access grant/denial events sent to the central station.
For the other events, if enabled, a report is sent to the central station.
NOTE: When Access Control and/or Home Automation is in use, Opening
Reports and Trace Reports are delayed 60 seconds.
If enabled, the system defeats Call Waiting on the first outgoing call attempt to
both the primary and secondary numbers.
NOTES:
After the panel's initial call to report the alarm, the panel may attempt to make
an additional call, perhaps for a cancel or a zone restoral. If Call Waiting is
not defeated, an operator at the central station attempting to contact the
premises (to verify whether the alarm is valid) hears the phone ringing
indefinitely and must to dispatch on the call.
DO NOT enable this feature unless Call Waiting is being used.
If enabled, backlighting for the keypad display remains on at all times.
Otherwise the backlighting comes on when a key is pressed.
NOTE: When a key is pressed, display backlighting turns on for all keypads in
that partition.
NOTE: This field affects only standard keypads, not AUI or graphic keypads.
If enabled, when more than 40 key depressions are received without a valid
sequence (arm, disarm, etc.), the control panel disables the wireless keypad.
The inhibit is removed once a valid key sequence is received from a wired
keypad.
Select the mode for output 1 on the J7 triggers.
NOTES:
Only one of the options may be active within the system.
Option 2 applies only to the partition enabled in field *15.
If enabled, the system produces chime annunciation on the external alarm
sounder.
Select the partition in which RF keypad is used.
If enabled, no trouble soundings occur on the keypad for transmitter check-in
failures.
Must be 0 for UL.
Select whether a callback from the control panel is required for downloading.
Must be 0 for UL installations.
Select the date format for display in the event log.
Select the frequency for the AC.
Must be set to 0 for U.S. and Canadian installations.