Honeywell VISTA-128BPEN Installation And Setup Manual page 72

Commercial burglary partitioned security system with scheduling
Table of Contents

Advertisement

Vista-128BPEN Installation and Setup Guide
FIELD
TITLE and DATA ENTRIES
Primary Subscriber's Account
*32
Number (partition-specific)
Enter 00-09; B-F (11-15)
Primary Phone Number
*33
Enter 0-9; #11 for *, #12 for #, #13 for a 2-
second pause.
Secondary Phone Number
*34
Enter 0-9; #11 for *, #12 for #, #13 for a 2-
second pause.
Download Phone Number
*35
Enter 0-9; #11 for *, #12 for #, #13 for a 2-
second pause.
Download ID Number
*36
Make entries as 2-digit numbers as follows:
00=0 01=1
06=6 07=7
12=C 13=D 14=E 15=F
Download Command Enables
*37
0 = disable
1 = enable
Prevent Zone XXX Bypass
*38
(partition-specific)
Enter a zone number (001-128).
Enter 000 if all zones can be bypassed.
Enable Open/Close Report for
*39
Installer Code (partition-specific)
0 = disable
1 = enable
Enable Open/Close report for
*40
Keyswitch
0 = disable
1 = enable
Normally Closed or EOLR (Zones
*41
2-8)
0 = EOLR used
1 = normally closed
Dial Tone Pause
*42
Enter the wait time for dial tone detection:
0 = 5 seconds; 1 = 11 seconds; 2 = 30
seconds.
5-4
02=2
03=3
04=4
05=5
08=8
09=9
10=A 11=B
EXPLANATION
Enter a 3- or 4-digit (depending on report format) primary subscriber account
number. Each number requires a 2-digit entry so as to allow entry of
hexadecimal digits (B-F). If a 3-digit account number is to be used, enter data
only in the first three locations, and enter * in the fourth location.
Enter the primary central station phone number, up to 17 digits. This is the
phone number the control will use to transmit Alarm and status messages to
the central station. Do not fill unused spaces.
NOTE: Backup reporting is automatic only if a secondary phone number is
entered.
Enter the secondary phone number, up to 17 digits. The secondary phone
number is used if communication on the primary number is unsuccessful, or if
split/dual reporting is desired. Do not fill unused spaces.
NOTE: If this field is programmed, a secondary subscriber account number
(field *90) must also be programmed.
Enter the downloading phone number, up to 17 digits. Do not fill unused
spaces.
NOTE: This field is applicable only if downloading is utilized.
Enter eight digits.
NOTE: This field is applicable only if downloading is utilized.
Enabling a function means that you are able to perform that function via the
ADEMCO Compass Downloading software.
Functions are as follows: Dialer Shutdown; System Shutdown; Not Used;
Remote Bypass; Remote Disarm; Remote Arm; Upload Program; Download
Program.
For UL installations, all entries must be 0.
Enter three digits for zone that cannot be bypassed by the user.
NOTES:
The actions manual bypass, group bypass, auto-stay, and STAY/INSTANT
arming modes cannot bypass any zone programmed in this field.
The system will not arm if the zone is programmed with the vent zone or force
arm fault attributes.
Force arm is not approved for ULC applications.
If enabled, whenever the Installer Code is used to arm or disarm the partition,
an open/close report is sent to the central station.
If enabled, whenever the keyswitch is used to arm or disarm the partition, an
open/close report is sent to the central station.
If 0, end-of-line resistors must be used on zones 2-8.
If 1 end-of-line resistors cannot be used and only normally closed devices
must be used.
Must be 0 for UL installations.
Enter the time the system waits for dial tone before dialing. Applies if true dial
tone is not selected in field *43.
Must be 0 for UL installations.

Hide quick links: