A 48 - ANOMALIES
IMPORTANT
The STARCREM cream cookers are fitted with a self-control system, indicating eventual anomalies in machine
operation; please find below wording which could appear on display, the eventual anomaly or cause and
action to be undertaken to eliminate defect.
WORDING ON
DISPLAY
OPEn+
acoustic signal
t 2 L+
acoustic signal
GB
t3V+
acoustic signal
H20+
acoustic signal
Al 4 +
acoustic signal
AL3 +
acoustic signal
Al 2 +
acoustic signal
First and tenth
leds blinking
n all cases, it is advisable to call technician, indicating type of wording, so that same may efficiently intervene.
I
54
- STARCREM 60/1 INV
ANOMALY/CAUSE
Lifted front half-lid
Lifted rear half-lid
Lifted motor bearing
Intervention of themal
switch of low speed mixer
motor.
Motor overheating.
Thermal switch of
high speed mixer motor
activated
Motor overheating
Pressure switch of
cooling system activated
Lack of water delivery
from water mains.
Excess mix temperature.
Probe temperature
measures 130°C.
Excess mix temperature.
Temperature probe has
measured - 15°C.
Temperature probe anomaly.
Short system interruption
of probe connection.
Interruption of the electric energy
(see Black out paragraph, page 51)
USER INSTRUCTIONS
REMEDY
Close front half-lid
Close rear half-lid
Close motor bearing
Press Reset button on inverter
Press Reset button (9).
The resetting of the thermic is
automatic and takes place when
the temperature of the engine
windings has gone below the
safety levels.
Press Reset button (9).
Check if water tap open.
Check water delivery from
water mains.
Stop the machine.
Call technical service.
Stop the machine.
Call technical service.
Stop the machine.
Call technical assistance.
Press Reset button (9).