A 28.1
Visualize cycle D on display (see program check).
Start-up cycle D by pressing button (1).
Resistances will be activated in sequence.
After 5 seconds low speed mixer will be activated.
At melting temperature 2D, COUNT-DOWN with resistances OFF will appear on
display.
At the end of COUNT-DOWN, the electrovalve and refrigeration compressor will
start operating.
At temperature 4D, STOP of electrovalve will appear.
At temperature 14D, compressor will start operating and alternated movement
will begin.
Operation for a time 15D with a pause 16D until temperature 3D.
In order to reach solidification temperature 17D, first resistance is started up.
GB
After five minutes, the acustic signal will be on, the bell and the temperature
leds will blink.
Above temperature is maintained with a precision of ±1°C.
A 28.2
Manual short solidification cycle
On terminating the solidification cycle and pressing cooking button, a short
solidification cycle begins.
Led 13 will be flashing and the two resistances will be activated with the low
speed mixer in operation until reaching temperature 19D.
At this temperature, there will be a pause of five minutes, with electrovalve and
refrigerator operating for the time 15D and 16D.
Once set 20D has been reached, refrigerator will stop.
Temperature led will flash for five minutes.
Maintenance with a precision of ± 1°C.
A 28.3
Automatic short solidification cycle with parameter 23D different from zero.
The manual solidification cycle is repeated at programmed intervals (one hour,
two hours, three hours).
A 28.4
Overnight preservation of chocolate
At any moment during short solidification process, heating cycle will begin by
pressing button (2) and led 14 will flash.
Low speed mixer will remain in operation until temperature 18D for ten minutes.
After ten minutes the low speed mixer functions every thirty minutes for five
minutes.