The X display origin is the X-axis value at the left edge of the display. For time
<X display
domain waveforms, it is the time at the start of the display. This value is treated
origin>
as a double precision 64-bit floating point number. If the value is zero then no
data has been acquired.
(See the :WAVeform:XDISplay? query.)
The Y display range is the Y-axis duration of the waveform which is displayed.
<Y display
For voltage waveforms, it is the amount of voltage across the display. If the
range>
value is zero then no data has been acquired.
(See the :WAVeform:YRANge? query.)
The Y-display origin is the Y-axis value at the center of the display. For voltage
<Y display
waveforms, it is the voltage at the center of the display. If the value is zero
origin>
then no data has been acquired.
(See the :WAVeform:YDISplay? query.)
<date> A string containing the date in the format DD MMM YYYY, where DD is the day,
1 to 31; MMM is the month; and YYYY is the year.
<time> A string containing the time in the format HH:MM:SS:TT, where HH is the hour,
0 to 23, MM is the minutes, 0 to 59, SS is the seconds, 0 to 59, and TT is the
hundreds of seconds, 0 to 99.
A string containing the model number and serial number of the oscilloscope in
<frame_
the format of MODEL#:SERIAL#.
model_#>
0 for RTIMe mode.
<acquisition
1 for ETIMe mode.
_mode>
2 not used.
3 for PDETect.
<completion> The completion value is the percent of time buckets that are complete. The
completion value is ignored when it is sent to the oscilloscope in the preamble.
(See the :WAVeform:COMPlete? query.)
0 for UNKNOWN units.
<x_units>
1 for VOLT units.
<y_units>
2 for SECOND units.
3 for CONSTANT units.
4 for AMP units.
5 for DECIBEL units.
The band pass consists of two values that are an estimation of the maximum
<max bandwidth
and minimum bandwidth limits of the source waveform. The bandwidth limit
limit>
is computed as a function of the selected coupling and filter mode.
<min bandwidth
(See the :WAVeform:BANDpass? query.)
limit>
Waveform Commands
PREamble
30-47

Advertisement

Table of Contents
loading

Table of Contents