2-11. ADDITIONAL CE
ELECTRICAL
STATEMENTS
Nov. 2007
•
The supply power cords shall be oil-resistant, sheathed
flexible cable, no lighter than ordinary polychloroprene or
other equivalent synthetic elastomer-sheathed cord.
•
It is recommended that a 30 mA rated protective device
such as a residual current circuit breaker (RCCB), or
ground fault circuit interrupter (GFCI), be used on the
fryer circuit.
•
Equipotential Ground Symbol =
(FOR EQUIPMENT WITH CE MARK ONLY!)
To prevent electric shock hazard this appliance must be
bonded to other appliances or touchable metal surfaces
in close proximity to this appliance with an equipotential
bonding conductor. This appliance is equipped with an
equipotential lug for this purpose. The equipotential lug is
marked with the following symbol
2-8
Model OFE/OFG/OEA/OGA-341, 342
Model OFE/OFG/OEA/OGA-341, 342
.