2-9. ELECTRICAL
REQUIREMENTS
OFG/OGA-340 SERIES
(Continued)
2-10. ELECTRICAL
REQUIREMENTS
OFE/OEA-340 SERIES
DRYWALL CONSTRUCTION
Secure I-bolt to a building
stud. Do not attach to drywall
only. Preferred installation is
approximately six inches to either
side of service. Cable restraint
must be at least six inches
shorter than flexible conduit.
July 2005
To avoid electrical shock, do not disconnect the ground
(earth) plug. This fryer must be adequately and safely
grounded. Refer to local electrical codes for correct
grounding (Earthing) proceduresor in absence of local codes,
with the National Electrical Code, ANSI/NFPA No. 70 Latest
Edition. Canadian models are supplied with a terminal box,
suitable for conduit connection. In Canada, all electrical
connections are to be made in accordance with CSA C221,
Canadian Electrical Code Part 1, and/or local codes.
Refer to the table below for supply wiring and fusing.
(Per Well)
Volts
Phase
208
3
240
3
380-415
3N+G
To avoid electrical shock, this appliance must be equipped
with an external circuit breaker which will disconnect all
ungrounded (unearthed) conductors. The main power switch
on this appliance does not disconnect all line conductors.
To avoid electrical shock, this fryer must be adequately and
safely grounded (earthed). Refer to local electrical codes
for correct grounding (earthing) procedures or in absence
of local codes, with The National Electrical Code, ANSI/
NFPA No. 70-(the current edition). In Canada, all electrical
connections are to be made in accordance with CSA C22.1,
Canadian Electrical Code Part 1, and/or local codes.
CE units require a minimum wire size of 6mm to be wired to
the terminal block. If a flexible power cord is used, it must be
HO7RN type.
Permanently connected electric fryers with casters must be
installed with flexible conduit and a cable restraint, when installed
in the United States. See illustration at left. Holes are available in
the rear fryer frame for securing the cable restraint to the fryer. The
cable restraint does not prevent the fryer from tipping.
2-7
Model OFE/OFG/OEA/OGA-341, 342
Model OFE/OFG/OEA/OGA-341, 342
Kw
Amps
22.0
61
22.0
53
22.0
32