4-3. SPECIAL PROGRAM
MODE (Continued)
Feb. 2007
q.
Press and release
r.
Press
to continue onto step 3 and follow
instructions in steps n, o, p, and q.
When all stages are set, you can continue to the next program
mode when you press
Special Program Mode.
Program Code Change (SP-16)
This allows the operator to change the program code (factory
set at 1, 2, 3) used to access Product Programming, Special
Programming, Clock Set, Data Comm, and Heat Control Modes.
a.
Follow steps 1 and 2 above.
b.
Press PROG until "SP-15" and "CHANGE, MGR
CODE? 1=YES" shows in display, along with "CODE".
c.
Press
. "ENTER NEW CODE, P=DONE, I=QUIT"
shows in display. Press product buttons with new code.
d.
If satisfied with code, press PROG. "REPEAT NEW
CODE, P=DONE, I=QUIT, shows in display. Press same
code buttons in step c.
e.
If satisfied with code, press PROG. "*CODE
CHANGE*" shows in display.
f.
If not satisfied with code, press INFO and
"*CANCELLED*" shows in display, then reverts back
to "SP-15" and "CHANGE, MGR CODE? 1=YES".
Then the above steps can be repeated
4-14
Model OFE/OFG/OEA/OGA-341, 342
Model OFE/OFG/OEA/OGA-341, 342
to set temperature for step 2.
, or press and hold