9.1.2
Inspection While the Power is ON (Robot is in operating)
Table 10: Inspection Position
Inspection Position
Check motion range
Move the cables back and forth
lightly to check whether the cables
are disconnected.
Push each arm in MOTOR ON
status to check whether backlash
exists.
Check whether unusual sound or
vibration occurs.
Measure the accuracy repeatedly
by a gauge.
9.2

Maintenance procedures

9.2.1
Battery pack replacement
Do not insert or pull out the motor connectors while the power to the
robot system is turned ON. Inserting or pulling out the motor
connectors with the power ON is extremely hazardous and may result
in serious bodily injury as the robot may move abnormally. It can also
may result in electric shock and/or malfunction of the robot system.
To shut off power to the robot system, pull out the power plug from the
power source. Be sure to connect the AC power cable to a power
receptacle. DO NOT connect it directly to a factory power source
Before performing any replacement procedure, turn OFF the
Controller and related equipment, and then pull out the power plug
from the power source.
Performing any replacement procedure with the power ON is
extremely hazardous and may result in electric shock and/or
malfunction of the robot system.
Inspection Place
Each joint
External cables
(including cable unit of
the robot)
Each arm
Whole
Whole
WARNING
E1101000117GB01
Dail
month
Quarterly
y
ly
MYS450L
half-
annuall
yearly
y
47