External Input/Output Section; Interface; Options - Unipulse F350 Operation Manual

Digital indicator
Table of Contents

Advertisement

■External input/output section

External input
External output

■Interface

SIF

■Options

BCD parallel data output (BCD)
RS-232C interface (232)
D/A converter voltage output (DAV)
83
Dry contact input circuit (minus common type) for hold control, etc.
(internal circuit power supply voltage 12V)
Open collector output circuit (sink type) for comparison output, etc.
Rated voltage: 30V, driving current: 30mA or less
2-wire serial interface for connecting a UNIPULSE-manufactured printer,
external display, etc.
Transmitting method: Asynchronous
Baud rate:
600bps
Output data:
Allocations to the GROSS area and NET area are
selected by the setting of "calculated value & ch1
value," "calculated value & ch2 value," or "ch1
value & ch2 value."
Open collector output circuit (sink type)
Data format:
Output rate:
Rated voltage:
Driving current:
Output data:
Transmitting method:
Baud rate:
Flow control:
Output range:
Load resistance:
D/A conversion speed:
Resolution:
Zero/span adjustment range:±10%F.S.
Non-linearity:
Output data:
10 SPECIFICATIONS
BCD or binary selectable
10、 30、 50、 100、 300、 500、 1000 times/sec.
30V
30mA or less
Selected by the setting of "calculated
value," "ch1 value," or "ch2 value," or
externally.
Asynchronous
9600bps to 57600bps
RTS/CTS controllable
±10V
2kΩ or more
Follows the original A/D conversion speed
1/10000
±0.05%F.S.
Selected by the setting of "calculated
value," "ch1 value," or "ch2 value."
Chapter
10
83

Advertisement

Table of Contents
loading