Analog Filter; Analog Filter Setting Method - Unipulse F350 Operation Manual

Digital indicator
Table of Contents

Advertisement

5 EXPLANATION OF INDICATED- VALUE-RELATED FUNCTIONS
5-2.

Analog filter

This is a low-pass filter for filtering input signals from the strain gauge sensor, and canceling
unwanted noise components (a filter that passes only the signals with a specific frequency or less,
and attenuates signals with higher frequencies). With an increase in the cut-off frequency, the
response becomes faster, but noise components may be displayed. It can be set for each of the ch1
and ch2 inputs.
≪Setting value≫

■Analog filter setting method

Chapter
5
36
36
0:3Hz
1:30Hz
2:300Hz
3:1kHz
1.
Select setting mode 3.
Press
FNC
2.
Set "Analog filter."
Press
twice. ⇒ " Analog filter " is displayed.
Press
, and present set value blinks.
Input the setting value with
Press
to validate it.(Initial value: 2)
3.
Press
twice to go back to the indicated value display.
ESC
twice.
.
Ch1 Ch 2
H I
LO
H I
LO
LO
H I
OK
PEAK
HOLD
Ch1 Ch 2
H I
H I
LO
LO