2 INSTALLATION & CONNECTION

■External I/O connection

Details of signal, see "8-1.External I/O" on page 60.
・How to connect external output (Sink type)
The external output circuit is operated through an open collector. A1(A7) COM1 is the common
Chapter
terminal. The open collector output capacity is 30mA and the withstand voltage is up to 30V.
2
(Minus common connection)
●Output Transistor Status
・How to connect external input
(minus common connection of no-voltage contact input type)
A signal is inputted to the signal input circuit by short-circuiting or opening the input terminal and
the COM2 terminal. Short-circuiting is effected by means of a contact (such as a relay or a switch)
or a noncontact (such as a transistor or an open-collector TTL)
+12V
14
14
F350
Sink type
A2 ~ A6
A8 ~ A10
Output
B2 ~ B6
Output COM1
A1, A7
B1
Vceo=30V(max)
Ic=30mA(max)
Output Data
OFF
ON
F350 Inside
Push
Switch
B8~12
B7
COM2
The external element is required to withstand Ic=10mA.
Leakage from the external element is required to be 100μA or below.
COM
+24V
DC24V
0V
Input
Tr
OFF
For driving, have an external power source ready.
(24V DC is shown in the illustration.)
ON
Open → OFF
Short → ON
Toggle
Switch
Relay
PLC etc.
Plus common connection
TTL Open Collector
(ON when IN is HI)
IN
IN