Connection; Power Input Terminal Connection - Unipulse F350 Operation Manual

Digital indicator
Table of Contents

Advertisement

2-2.

Connection

■Power input terminal connection

Connect an AC input cord. The input power source is free in the range of 100 to 240V AC (-15%,
+10%).
The frequency is 50/60Hz.
Make connections to the terminal block with a solderless terminal within 6mm in diameter as
shown in the illustration so as not to let the tip of the cable spread out.
1.
2.
3.
4.
5.
6.
9
Make sure that no power is applied.
Remove the screws (two), and remove
the terminal block cover.
Remove the two screws
the terminal block
.
Align the solderless terminals with
the screw holes, and then tighten
the screws.
L
:Black
N
:White
Install the terminal block cover, and fix it with the screws (two).
Remove the screws(M4) of the protective ground, align the crimp contacts
with the screw holes, and then tighten the screws.
:Green/ Yellow
* The protective ground is internally connected with
2 INSTALLATION & CONNECTION
at
(M3)
Color description are for the attached
AC input cord.
Within 6mm
Black
White
Green/Yellow
frame ground.
9
Chapter
2

Advertisement

Table of Contents
loading