9 OPTION INTERFACE
■Output rate
《Setting value》
* When the A/D conversion speed is 300 times/sec., settings are available up to 4: 300
◇Output rate setting method
Chapter
9
■BCD/binary select
The output data selection can be changed to binary.
68
68
0:10
4:300
1:30
5:500
2:50
6:1000
3:100
【times/sec.】
[times/sec.].
Point
Even if this setting is changed, A/D conversions speed does not change.
Make the output rate slower when reading fails due to a low processing
performance of the device that should receive BCD.
1.
Select setting mode 5.
Press
→
FNC
2.
Set "Output rate."
Press
Twice. ⇒ "Output rate" is displayed.
Press
, and present set value blinks.
Input the setting value with
(Initial value:3)
Press
to validate it.
3.
Press
twice to go back to the indicated value display.
ESC
《Setting value》
0:BCD
1:Binary
four times.
.
Ch1
Ch 2
H I
LO
H I
LO
H I
OK
LO
PEAK
HOLD
Ch1 Ch 2
H I
LO
H I
LO