Rs-232-C Serial Command Control - Panasonic Aicure ANUP5255V2 Operation Manual

Uv-curing system
Table of Contents

Advertisement

Aicure ANUP5255V2
Setting and UV irradiation by external devices

10.3 RS-232-C serial command control

Intensity setting and others can be controlled under serial signals by connecting the "RS-232-C"
terminal on the back of the AICURE body with an external device (personal computer, PLC).
Control is accomplished by an interactive procedure in which a command is sent from the external
device to the AICURE, and the response is returned from the AICURE to the external device.
Aicure
・The machine returns the response whenever a command comes in. If no response
Caution:
comes back after the transmission of a command, a transmission error should be
assumed. Then error handling should be done.
・Up to 32 AICUREs can be connected to one external device. When sending a
command, specify the address (device number). For the address, see Chapter 8
Address Setting/Language Switching.
■Command list
Command code
RS
RK
RU
Read
RUS
RT
WU
Write
WUS
50
Command
Response
(monitor data) or
error message
Personal computer
Command type
UV intensity readout
Intensity control rate
readout
Intensity setting
value readout
Intensity selection
readout
Lamp ON time
readout
Intensity selection
write
Intensity setting
value write
Control detail
Reads the intensity value displayed on
the LCD.
Reads the intensity control rate
displayed on the LCD.
Reads the intensity setting value set in
the body.
Reads the presence or absence of
selection of intensity settings.
Reads the cumulative lamp ON time
stored in the body, and the presence or
absence of lamp-change time.
Sets the intensity selection in the body.
Writes the intensity setting value
(intensity, timer setting value).