3-5-9 Counter reset input

ON
TRIG. IN
OFF
ON
SELECT 0 to 2
IN
OFF
ON
D0 to D7 IN
(Counter No.)
OFF
ON
SET IN
OFF
ON
READY OUT
OFF
ON
MARKING OUT
OFF
ON
SET OK OUT
OFF
Item
Period
T1
10 ms or more
T2
0 ms or more
T3
2 to 510 ms
T4
T5
0.5 ms or more
*1 : To reset the counter value, input SELECT 0 to 2 as the table below.
Number input target
Counter reset No.
*2 : Specify the counter No. to be reset at D0 to D7. Refer to "3-3-4 Signals on I/O connector" (P.94) for the detail.
T1
Remarks
Keep the ON status for 10 ms or more.
Keep the input until the SET OK turns ON.
One-shot output. Set the output time on the environment setting screen. There is a
margin for the setting value.
• When laser pumping is completed:
Time for data creation. It varies depending on the quantity of data to be marked.
• When laser pumping is not completed:
Time for data creation or time for laser pumping, whichever is longer.
After a lapse of 0.5ms or more from specifying SELECT 0 IN to SELECT 2 IN and D0 IN
to D7 IN, turn on SET IN.
SELECT 0 (No. 20)
OFF
ME-LPS-SSM-8
*1
*2
T5
T2
T4
T3
SELECT 1 (No. 21)
OFF
SELECT 2 (No. 22)
ON