⿎ Example of command settings
Condition:
Counter No. = 0, Current value = 1234, Starting value = 0, End value = 9999, Step value = 1,
Count timing = 8, Reset at date change = 1
• Setting
Transmission data
• Readout
Transmission data
Response data
• If the counter is reset at date change during on-the-fly marking operation (single trigger mode), the marking trigger ready
status turns off momentary and there is a case that the next marking could not be executed due to Warning E751.
• With LP-400/V compatible command mode, the counter numbers 4 to 15 and global counter numbers 20 to 31 cannot be
set and readout.
• With LP-400/V compatible command mode, the counter value larger than 999999 cannot be set and readout.

3-6-2 Counter reset: CTR

Resets the current value to the starting value.
⿎ Setting request data
Start
CTR
code
⿎ Data description
Data length
Name
Counter 0
Counter 1
Counter 2
Counter 3
Global counter 16
Global counter 17
Global counter 18
Global counter 19
Total data length
• The setting changed by this command is saved in the laser marker without overwriting to the file.
• If the counter is reset during on-the-fly marking operation, the marking trigger ready status turns off momentary and
there is a case that the next marking could not be executed due to Warning E751.
• With LP-400/V compatible command mode, the counter numbers 4 to 15 and global counter numbers 20 to 31 cannot be
reset.
⿎ Example of command settings
Condition:
To reset counter 0 and 16
• Setting
Transmission data
80
[STX]
CNT
[STX]
CNT
[STX]
CNT
[Counter 0] [Counter 1] [Counter 2] [Counter 3]
[Global counter 16] [Global counter 17]
S
[Global counter 18] [Global counter 19]
Data contents
[byte]
1
1
1
1
"0": Do not reset
"1": Reset
1
1
1
1
8
The data length is fixed.
[STX]
CTR
S
000123400000000999900000181
R
0
[CR]
A
000123400000000999900000181
8-byte
S
10001000
[CR]
ME-LP-GS-SR-COMP-3
[CR]
[CR]
(Check
End code
sum)
Remarks